AC Fans

Image Part Number Description / PDF Quantity Rfq
R2D180-AL10-13

R2D180-AL10-13

ebm-papst Inc.

MOTORIZED IMPELLER

0

A2S130-AE03-12

A2S130-AE03-12

ebm-papst Inc.

AC AXIAL FAN

0

FE077-A/125850

FE077-A/125850

ebm-papst Inc.

FAN AXIAL 3-PH 925X280MM 460VAC

0

G3G125-AA20-10

G3G125-AA20-10

ebm-papst Inc.

MOTORIZED IMPELLER

0

A3G250-AC54-01

A3G250-AC54-01

ebm-papst Inc.

AC AXIAL FAN

0

RD20S-4/110898

RD20S-4/110898

ebm-papst Inc.

FAN BLWR CENT 314X378MM 230VAC

0

R2E190-RA50-16

R2E190-RA50-16

ebm-papst Inc.

MOTORIZED IMPELLER

0

55410.82470

55410.82470

ebm-papst Inc.

FAN BLOWER CROSSFLOW

0

QR06A-2/106352

QR06A-2/106352

ebm-papst Inc.

FAN BLOWER CF 420X158MM 230VAC

0

R4E225-AC15-18

R4E225-AC15-18

ebm-papst Inc.

FAN IMP MTRZD 225X63MM 115VAC

0

FC063-6/105127

FC063-6/105127

ebm-papst Inc.

FAN AXIAL 805X218MM 230VAC WIRE

0

55442.70061

55442.70061

ebm-papst Inc.

FAN BLOWER CF 300X79MM 48VAC

0

A4E300-AA01-01

A4E300-AA01-01

ebm-papst Inc.

AC AXIAL FAN

0

EG1G-230-146-01

EG1G-230-146-01

ebm-papst Inc.

AC AXIAL FAN

0

QK10A-2/111589

QK10A-2/111589

ebm-papst Inc.

FAN BLOWER CF 480X200MM 115VAC

0

RH40M-4/203473

RH40M-4/203473

ebm-papst Inc.

FAN IMP MTRZD 404X188MM 230VAC

0

S2D300-CP02-34

S2D300-CP02-34

ebm-papst Inc.

FAN AXIAL

0

R3G220-AE50-11

R3G220-AE50-11

ebm-papst Inc.

AC AXIAL FAN

0

W2K121-AB11-13

W2K121-AB11-13

ebm-papst Inc.

FAN AXIAL 127X38MM 115VAC TERM

0

W2D250-CI02-16

W2D250-CI02-16

ebm-papst Inc.

FAN AXIAL

0

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction