AC Fans

Image Part Number Description / PDF Quantity Rfq
W4E350-DA06-52

W4E350-DA06-52

ebm-papst Inc.

FAN AXIAL

4

W2E250-HJ32-10

W2E250-HJ32-10

ebm-papst Inc.

FAN AXIAL

0

W2E250-CM06-01

W2E250-CM06-01

ebm-papst Inc.

FAN AXIAL

0

W2D250-GA02-07

W2D250-GA02-07

ebm-papst Inc.

FAN AXIAL

0

EE1G-115-140-02

EE1G-115-140-02

ebm-papst Inc.

BLOWER

0

W3G710-GS28-11F

W3G710-GS28-11F

ebm-papst Inc.

FAN AXIAL

0

8550TA

8550TA

ebm-papst Inc.

FAN AXIAL 76X37MM 230VAC WIRE

0

4600TZ

4600TZ

ebm-papst Inc.

FAN AXIAL 108X37MM 115VAC WIRE

0

55442.65051

55442.65051

ebm-papst Inc.

FAN BLOWER CF 2X240X79MM 115VAC

0

W4E420-CP02-70

W4E420-CP02-70

ebm-papst Inc.

FAN AXIAL 544X80MM 230VAC WIRE

0

W2E142-BB01-21

W2E142-BB01-21

ebm-papst Inc.

FAN AXIAL 230VAC 172X150X38MM

0

S4E450-AP01-71

S4E450-AP01-71

ebm-papst Inc.

FAN AXIAL 522X159MM 230VAC WIRE

0

W6E315-CP02-70

W6E315-CP02-70

ebm-papst Inc.

FAN AXIAL 397X74MM 230VAC WIRE

0

W4E250-CI36-70

W4E250-CI36-70

ebm-papst Inc.

FAN AXIAL 320X85MM 115VAC WIRE

0

W3G910-GZ01-67F

W3G910-GZ01-67F

ebm-papst Inc.

FAN AXIAL

0

55416.34030

55416.34030

ebm-papst Inc.

FAN BLWR CF 2X240X605MM 115VAC

0

W3G800-GV01-67F

W3G800-GV01-67F

ebm-papst Inc.

FAN AXIAL

0

W3G710-GU21-09F

W3G710-GU21-09F

ebm-papst Inc.

FAN AXIAL

0

55416.30130

55416.30130

ebm-papst Inc.

FAN BLWR CF 240X108MM 115VAC

0

R4E310-AO32-11

R4E310-AO32-11

ebm-papst Inc.

MOTORIZED IMPELLER

0

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction