AC Fans

Image Part Number Description / PDF Quantity Rfq
OAB190-22-1

OAB190-22-1

Orion Fans

FAN IMP MTRZD 190X70 230V W/CAP

1

A2E250-AE65-01

A2E250-AE65-01

ebm-papst Inc.

AC AXIAL FAN

0

FDA2-R17251NBKW3D

FDA2-R17251NBKW3D

Qualtek Electronics Corp.

FAN AXIAL 172X51MM 115VAC WIRE

0

OA172SAN-11-1WB

OA172SAN-11-1WB

Orion Fans

FAN AXIAL 172X50.8MM 115VAC WIRE

0

SF23092A-2092HST.GN

SF23092A-2092HST.GN

Sunon

FAN AXIAL 91.5X25.5MM 220/240VAC

5

FMA1-12038WBHW12

FMA1-12038WBHW12

Qualtek Electronics Corp.

EC FAN, 120X120X38MM, 2-BALL BEA

98

CF4113HBL-000U-AE9

CF4113HBL-000U-AE9

Sunon

FAN AXIAL 120X38MM 100-240V IP68

51

OA109AP-22-1WB

OA109AP-22-1WB

Orion Fans

FAN AXIAL 120X38MM 230VAC WIRE

280

R2E175-AC77-05

R2E175-AC77-05

ebm-papst Inc.

MOTORIZED IMPELLER

0

109S304

109S304

Sanyo Denki

FAN 172X51MM 115VAC SIDE CUT

15

3610PS-10T-B30-B00

3610PS-10T-B30-B00

NMB Technologies Corp.

FAN AXIAL 92.5X25MM 100VAC TERM

11

UF12A23-BTHNSR

UF12A23-BTHNSR

Mechatronics

FAN 120X38MM 230V IP55 SALT FOG

116

OA180AN-11-1WB1856

OA180AN-11-1WB1856

Orion Fans

FAN AXIAL 176X89MM 115VAC WIRE

15

UF12A12-BTLNR

UF12A12-BTLNR

Mechatronics

FAN 120X38MM 115V IP55 TERM

0

OA172AP-11-1TB

OA172AP-11-1TB

Orion Fans

FAN AXIAL 172X51MM 115VAC TERM

59

19031844A

19031844A

Comair Rotron

FAN AXIAL 172X55MM 230VAC MA77B3

66

OAB220-11-1

OAB220-11-1

Orion Fans

FAN IMP MTRZD 220X71 115V W/CAP

0

FDA2-17251QBHW4F-L

FDA2-17251QBHW4F-L

Qualtek Electronics Corp.

FAN AXIAL 172X51MM 230VAC WIRE

0

R2E250-AW50-05

R2E250-AW50-05

ebm-papst Inc.

MOTORIZED IMPELLER

72

R4E400-AP15-10

R4E400-AP15-10

ebm-papst Inc.

MOTORIZED IMPELLER

22

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction

RFQ BOM Call Skype Email
Top