Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
3214362

3214362

Phoenix Contact

CONN TERM BLK FEED THRU 10-26AWG

155

3031416

3031416

Phoenix Contact

CONN TERM BLK GROUND 10-28AWG

492800

3036563

3036563

Phoenix Contact

CONN TERM BLK DISCONN 10-28AWG

241400

3209536

3209536

Phoenix Contact

CONN TERM BLK GROUND 12-26AWG

192345400

2295567

2295567

Phoenix Contact

CONN TERM BLK FEED THRU 12-24AWG

0

3073953

3073953

Phoenix Contact

CONN TERM BLK DISCONNECT 6-20AWG

55

0719139

0719139

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

3

3036369

3036369

Phoenix Contact

CONN TERM BLK DISCONN 10-28AWG

774900

3046304

3046304

Phoenix Contact

CONN TERM BLK FEED THRU 6-20AWG

11152150

3050387

3050387

Phoenix Contact

CONN TERM BLK DISCONN 14-20AWG

0

3213957

3213957

Phoenix Contact

CONN TERM BLK DISCONN 12-26AWG

0

1414103

1414103

Phoenix Contact

CONN TERM BLK FEED THRU 12-24AWG

8250

3064043

3064043

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

0

3036042

3036042

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

325

3001938

3001938

Phoenix Contact

CONN TERM BLK DISCONNECT 8-26AWG

996396

2772077

2772077

Phoenix Contact

CONN TERM BLK FEED THRU 6-24 AWG

2139

3044128

3044128

Phoenix Contact

CONN TERM BLK GROUND 10-26AWG

1925

3072815

3072815

Phoenix Contact

CONN TERM BLK DISCONNECT 8-20AWG

0

3244481

3244481

Phoenix Contact

CONN TERM BLK ISOLATED 12-24 AWG

46100

3047660

3047660

Phoenix Contact

CONN TERM BLK FEED THRU 6-20 AWG

0

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections
RFQ BOM Call Skype Email
Top