Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
3031432

3031432

Phoenix Contact

CONN TERM BLK FEED THRU 10-28AWG

0

3003017

3003017

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

2316000

3072817

3072817

Phoenix Contact

CONN TERM BLK FEED THRU 8-20 AWG

0

3208333

3208333

Phoenix Contact

CONN TERM BLK GROUND 14-26AWG

7971300

3210400

3210400

Phoenix Contact

CONN TERM BLK DISCONN 12-26AWG

50

3074460

3074460

Phoenix Contact

CONN TERM BLK FEED THRU 10-26AWG

7

3048519

3048519

Phoenix Contact

CONN TERM BLK DISCONNECT

24

3064069

3064069

Phoenix Contact

CONN TERM BLK DISCONNECT 8-24AWG

70

3031571

3031571

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

50

3100020

3100020

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

36

3214080

3214080

Phoenix Contact

POTENTIAL COLLECTIVE TERMINAL, C

36500

3031254

3031254

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

4395150

3209583

3209583

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

6221250

3011012

3011012

Phoenix Contact

CONN TERM BLK FEED THRU 16-24AWG

0

3050358

3050358

Phoenix Contact

CONN TERM BLK GROUND 14-20AWG

0

3076329

3076329

Phoenix Contact

CONN TERM BLK FEED THRU 3/0-6AWG

0

0561002

0561002

Phoenix Contact

CONN TERM BLK FEED THRU 12-24AWG

50

3210326

3210326

Phoenix Contact

CONN TERM BLK DISCONN 16-26AWG

0

3209607

3209607

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

0

1086477

1086477

Phoenix Contact

TERM BLOCK HIGH-CURRENT

10

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections