Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
3006182

3006182

Phoenix Contact

CONN TERM BLK FEED THRU 2-18 AWG

31

3214364

3214364

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

50

3005840

3005840

Phoenix Contact

CONN TERM BLK FEED THRU 14-30AWG

56

3046320

3046320

Phoenix Contact

CONN TERM BLK FEED THRU 6-20 AWG

4733750

3005646

3005646

Phoenix Contact

CONN TERM BLK DISCONNECT 6-24AWG

5152

2794932

2794932

Phoenix Contact

CONN TERM BLK FEED THRU 10-26AWG

0

3210185

3210185

Phoenix Contact

CONN TERM BLK DISCONN 12-26AWG

942000

3048357

3048357

Phoenix Contact

CONN TERM BLK DISCONNECT 2-16AWG

5

3037481

3037481

Phoenix Contact

CONN TERM BLK FEED THRU 10-28AWG

0

3074169

3074169

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

2061350

3000539

3000539

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

19150

3205080

3205080

Phoenix Contact

CONN TERM BLK FEED THRU 16-24AWG

58

3260055

3260055

Phoenix Contact

CONN TERM BLK FEED THRU 1/0-8AWG

0

3212069

3212069

Phoenix Contact

CONN TERM BLK FEED THRU 2-14 AWG

0

1086475

1086475

Phoenix Contact

TERM BLOCK HIGH-CURRENT

76

2775249

2775249

Phoenix Contact

CONN TERM BLK FEED THROUGH GRAY

95

3005073

3005073

Phoenix Contact

CONN TERM BLK FEED THRU 6-24 AWG

1621

0309109

0309109

Phoenix Contact

CONN TERM BLK DISCONNECT 8-26AWG

2808900

3213949

3213949

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

232

1402940

1402940

Phoenix Contact

CONN TERM BLK FEED THRU 10-26AWG

28832950

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections
RFQ BOM Call Skype Email
Top