Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
ATX25F

ATX25F

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 2-14 AWG

0

ATD4

ATD4

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 10-20AWG

0

ATX35BG

ATX35BG

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 2-18 AWG

0

ATB35F

ATB35F

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 2-8 AWG

0

ASBM21G

ASBM21G

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 14-22AWG

0

ATB25F

ATB25F

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 2-14 AWG

0

ATX25BK

ATX25BK

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 2-14 AWG

0

ATF4

ATF4

Socapex (Amphenol Pcd)

CONN TERM BLK DISCONN 10-22AWG

0

ATX4

ATX4

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 10-22AWG

0

ATBB4BG

ATBB4BG

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 6-22 AWG

0

ATB50BK

ATB50BK

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 2/0-6AWG

0

ATB2Y

ATB2Y

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 14-24AWG

0

ATD1F4

ATD1F4

Socapex (Amphenol Pcd)

CONN TERM BLK DISCONN 10-22AWG

0

ATDA4BK

ATDA4BK

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 10-22AWG

0

ASMA41W

ASMA41W

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 12-22AWG

0

ATD1F4BU

ATD1F4BU

Socapex (Amphenol Pcd)

CONN TERM BLK DISCONN 10-22AWG

0

ATM42BU

ATM42BU

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 10-22AWG

0

ASBG6

ASBG6

Socapex (Amphenol Pcd)

CONN TERM BLK GROUND 8-22 AWG

0

ASMA42G

ASMA42G

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 12-22AWG

0

ATX4W

ATX4W

Socapex (Amphenol Pcd)

CONN TERM BLK FEED THRU 10-22AWG

0

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections
RFQ BOM Call Skype Email