Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
1SNK516061R0000

1SNK516061R0000

TE Connectivity's Sigma Inductors

POW SNK SCREW

40

1SNK516011R0000

1SNK516011R0000

TE Connectivity's Sigma Inductors

POW SNK SCREW

78

1SNK506061R0000

1SNK506061R0000

TE Connectivity's Sigma Inductors

AUT SNK SCREW

87

1SNK710150R0000

1SNK710150R0000

TE Connectivity's Sigma Inductors

POW SNK PI-SPRING

100

1SNK710151R0000

1SNK710151R0000

TE Connectivity's Sigma Inductors

POW SNK PI-SPRING

14

1SNK706066R0000

1SNK706066R0000

TE Connectivity's Sigma Inductors

AUT SNK PI-SPRING

100

1SNK508424R0000

1SNK508424R0000

TE Connectivity's Sigma Inductors

AUT SNK SCREW

45

1SNK522010R0000

1SNK522010R0000

TE Connectivity's Sigma Inductors

POW SNK SCREW

8

1SNK506150R0000

1SNK506150R0000

TE Connectivity's Sigma Inductors

AUT SNK SCREW

89

1SNK508320R0000

1SNK508320R0000

TE Connectivity's Sigma Inductors

POW SNK SCREW

50

1SNK506321R0000

1SNK506321R0000

TE Connectivity's Sigma Inductors

AUT SNK SCREW

50

1SNK710030R0000

1SNK710030R0000

TE Connectivity's Sigma Inductors

POW SNK PI-SPRING

60

1SNK506064R0000

1SNK506064R0000

TE Connectivity's Sigma Inductors

AUT SNK SCREW

86

1SNK505214R0000

1SNK505214R0000

TE Connectivity's Sigma Inductors

AUT SNK SCREW

43

1SNK705011R0000

1SNK705011R0000

TE Connectivity's Sigma Inductors

AUT SNK PI-SPRING

1761

1SNK705330R0000

1SNK705330R0000

TE Connectivity's Sigma Inductors

AUT SNK PI-SPRING

50

1SNK505320R0000

1SNK505320R0000

TE Connectivity's Sigma Inductors

AUT SNK SCREW

98

1SNK705511R0000

1SNK705511R0000

TE Connectivity's Sigma Inductors

AUT SNK PI-SPRING

25

1SNK506068R0000

1SNK506068R0000

TE Connectivity's Sigma Inductors

AUT SNK SCREW

50

1SNK508311R0000

1SNK508311R0000

TE Connectivity's Sigma Inductors

TEST AND MEASUREMENT TB

32

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections
RFQ BOM Call Skype Email
Top