Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
6102000

6102000

Curtis Industries

CONN TERM BLK FEED THRU 12-24AWG

0

6110000

6110000

Curtis Industries

CONN TERM BLK FEED THRU 6-20 AWG

0

6204009

6204009

Curtis Industries

CONN TERM BLK FEED THRU 10-24AWG

0

6302000

6302000

Curtis Industries

CONN TERM BLK FEED THRU 14-26AWG

0

6204010

6204010

Curtis Industries

CONN TERM BLK FEED THRU 10-24AWG

0

6106005

6106005

Curtis Industries

CONN TERM BLK FEED THRU 8-22 AWG

0

6204008

6204008

Curtis Industries

CONN TERM BLK FEED THRU 10-24AWG

0

6204100

6204100

Curtis Industries

CONN TERM BLK FEED THRU 10-24AWG

0

6104000

6104000

Curtis Industries

CONN TERM BLK FEED THRU 10-24AWG

0

6104007

6104007

Curtis Industries

CONN TERM BLK FEED THRU 10-24AWG

0

6170006

6170006

Curtis Industries

CONN TERM BLK FEED THRU 3/0-4AWG

0

6202110

6202110

Curtis Industries

CONN TERM BLK FEED THRU 12-24AWG

0

6204002

6204002

Curtis Industries

CONN TERM BLK FEED THRU 10-24AWG

0

6110140

6110140

Curtis Industries

CONN TERM BLK DISCONNECT 6-20AWG

0

6104008

6104008

Curtis Industries

CONN TERM BLK FEED THRU 10-24AWG

0

6110007

6110007

Curtis Industries

CONN TERM BLK FEED THRU 6-20 AWG

0

6204046

6204046

Curtis Industries

CONN TERM BLK FEED THRU 10-24AWG

0

6110120

6110120

Curtis Industries

CONN TERM BLK DISCONNECT 6-20AWG

0

6104600

6104600

Curtis Industries

CONN TERM BLK DISCONN 10-24AWG

0

6504008

6504008

Curtis Industries

CONN TERM BLK FEED THRU 10-24AWG

0

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections
RFQ BOM Call Skype Email
Top