Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
1167340000

1167340000

Weidmuller

CONN TERM BLK DISCONN 12-26AWG

3650

0352780000

0352780000

Weidmuller

NT 6/32 PA BU

0

0396860000

0396860000

Weidmuller

CONN TERM BLK FEED THRU 12-22AWG

0

1677130000

1677130000

Weidmuller

CONN TERM BLK FEED THROUGH

0

1024650000

1024650000

Weidmuller

CONN TERM BLK FEED THRU 2/0-6AWG

0

0286720000

0286720000

Weidmuller

SAKG 32 III/32 KRG BN

90

911854

911854

Weidmuller

CONN TERM BLK FEED THROUGH

0

0210260000

0210260000

Weidmuller

DK 4/35 LD 24VDC

0

912025

912025

Weidmuller

CONN TERM BLK FEED THRU 12-26AWG

0

0299560000

0299560000

Weidmuller

CONN TERM BLK DISCONN 12-26AWG

0

1779020000

1779020000

Weidmuller

CONN TERM BLK DISCONN 12-26AWG

0

1021800000

1021800000

Weidmuller

CONN TERM BLK FEED THRU 12-26AWG

0

1027500000

1027500000

Weidmuller

CONN TERM BLK FEED THROUGH BEIGE

20

1031300000

1031300000

Weidmuller

CONN TERM BLK FEED THRU 12-26AWG

0

0590060000

0590060000

Weidmuller

CONN TERM BLK FEED THRU 12-26AWG

0

1881650000

1881650000

Weidmuller

CONN TERM BLK DISCONN 10-26AWG

0

1033800000

1033800000

Weidmuller

CONN TERM BLK FEED THRU 10-26AWG

0

1733490000

1733490000

Weidmuller

CONN TERM BLK FEED THRU 8-22 AWG

0

912022

912022

Weidmuller

CONN TERM BLK FEED THRU 12-26AWG

0

1030400000

1030400000

Weidmuller

CONN TERM BLK FEED THRU 10-26AWG

0

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections
RFQ BOM Call Skype Email
Top