Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
2788090

2788090

Phoenix Contact

CONN TERM BLK FEED THRU 12-24AWG

0

2000-2201

2000-2201

WAGO

DOUBLE-DECK TERMINAL BLOCK; THRO

40

ODLG2.5A(I.S)

ODLG2.5A(I.S)

Altech Corporation

DIN TERM BLK SCREW DBL LEVEL

58150

ODL2.5(I.S)

ODL2.5(I.S)

Altech Corporation

DIN TERM BLK SCREW DBL LEVEL

470550

0711580

0711580

Phoenix Contact

CONN TERM BLK 12-24 AWG BLACK

0

3001501

3001501

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

100

CYDLF4

CYDLF4

Altech Corporation

DIN TERM BLK SCREW FUSE

1161450

CYG4

CYG4

Altech Corporation

DIN TERM BLK SCREW GRND

145300

0441711

0441711

Phoenix Contact

CONN TERM BLK DISCONN 14-24AWG

1

3046605

3046605

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

0

1209.2

1209.2

Conta-Clip

CONN TERM BLK FEED THRU 12-22AWG

100

1SNK516010R0000

1SNK516010R0000

TE Connectivity's Sigma Inductors

POW SNK SCREW

35

3210356

3210356

Phoenix Contact

CONN TERM BLK FEED THRU 16-26AWG

99

7904170000

7904170000

Weidmuller

CONN TERM BLK GROUND 10-26AWG

58200

1745400000

1745400000

Weidmuller

CONN TERM BLK DL DISCON 12-26AWG

2060

DK4N

DK4N

DINKLE Corporation USA

SCREW TERM BLK FEED THROUGH 22~1

74943

3006153

3006153

Phoenix Contact

CONN TERM BLK FEED THRU 4-22 AWG

19150

1020020000

1020020000

Weidmuller

CONN TERM BLK FEED THRU 12-30AWG

461800

0110060000

0110060000

Weidmuller

CONN TERM BLK FEED THRU 6-14 AWG

96

CYDLK4

CYDLK4

Altech Corporation

DIN TERM BLK SCREW DISCONN

100100

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections