Power Entry Connectors - Inlets, Outlets, Modules

Image Part Number Description / PDF Quantity Rfq
44R01-1131-250

44R01-1131-250

Power Dynamics, Inc.

PWR ENT MOD RCP IEC 320-C14 PNL

25

HGN-369-3

HGN-369-3

Power Dynamics, Inc.

PWR ENT MOD RCP IEC 320-C14 PNL

4

42R37-3154-160

42R37-3154-160

Power Dynamics, Inc.

PWR ENT MOD RCP IEC 320-C14 PNL

4

44R02-5121-250

44R02-5121-250

Power Dynamics, Inc.

PWR ENT MOD RCP IEC 320-C13 PNL

8

460R9W

460R9W

Power Dynamics, Inc.

PWR ENT RCP PIN&SLEEVE PNL SCREW

1

42R37-3124-150

42R37-3124-150

Power Dynamics, Inc.

PWR ENT MOD RCP IEC 320-C14 PNL

3

PD-20-2

PD-20-2

Power Dynamics, Inc.

PWR ENT RCPT NEMA 5-20R PNL IDC

25

320R6W

320R6W

Power Dynamics, Inc.

PWR ENT RCP PIN&SLEEVE PNL SCREW

10

44R01-3151-250

44R01-3151-250

Power Dynamics, Inc.

PWR ENT RCP IEC 320-C14 PNL SLDR

52

SCM460MI7W

SCM460MI7W

Power Dynamics, Inc.

PWR ENT PLUG PIN&SLEEVE PNL SCRW

3

560P9W

560P9W

Power Dynamics, Inc.

PWR ENT PLUG PIN&SLEEVE STR SCRW

2

42R32-3121-150

42R32-3121-150

Power Dynamics, Inc.

PWR ENT MOD RCP IEC 320-C14 PNL

80

560P7W

560P7W

Power Dynamics, Inc.

PWR ENT PLUG PIN&SLEEVE STR SCRW

0

PD-15-1-GY

PD-15-1-GY

Power Dynamics, Inc.

PWR ENT RCPT NEMA 5-15R PNL QC

10

PD-43R03-21

PD-43R03-21

Power Dynamics, Inc.

PWR ENT RCPT IEC 320-C13 PNL QC

0

42R07-1121

42R07-1121

Power Dynamics, Inc.

PWR ENT RCPT IEC 320-C20 PNL QC

13

PBH20Q-00-1AF

PBH20Q-00-1AF

Power Dynamics, Inc.

PWR ENT RCPT IEC 320-C20 PNL QC

34

42R02-3114-250

42R02-3114-250

Power Dynamics, Inc.

PWR ENT MOD RCP IEC 320-C18 PNL

0

43R03-3122-250

43R03-3122-250

Power Dynamics, Inc.

PWR ENT MOD RCP IEC 320-C15 PNL

10

460B9W

460B9W

Power Dynamics, Inc.

PIN & SLEEVE, INLET, IP67

7

Power Entry Connectors - Inlets, Outlets, Modules

1. Overview

Power entry connectors are electro-mechanical devices designed to safely establish electrical connections between equipment and power sources. They serve as critical interfaces in AC/DC power systems, ensuring reliable energy transmission while meeting safety and regulatory standards. Their importance spans across industries where stable power delivery and user protection are paramount.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
IEC Appliance InletsStandardized C13/C19 types, detachable connectionsComputers, servers, medical devices
NEMA ReceptaclesNon-locking/Locking configurations (5-15P/R, L5-30P/R)Industrial machinery, construction equipment
Modular Power Entry ModulesIntegrated filtering, switching, and fused protectionData centers, test equipment
Medical-Grade ConnectorsDouble-insulated, low-leakage current designPatient monitors, MRI machines

3. Structure and Components

Typical construction includes:

  • Thermoplastic housing (UL94 V-0 rated)
  • Copper alloy contact springs (phosphor bronze)
  • Insulation barriers (glass-reinforced epoxy)
  • Termination options: Screw/clamp terminals or PCB mounts
  • Integrated features: EMI filters, circuit breakers, LED indicators

4. Key Technical Specifications

ParameterSignificance
Rated Voltage (50-600V AC/DC)Determines maximum operating potential
Current Rating (1-63A)Defines safe continuous load capacity
Contact Resistance (<5m )Impacts power efficiency and thermal performance
Dielectric Withstanding Voltage (1.5-4kV)Safety isolation capability
Temperature Range (-40 C to +125 C)Environmental operational limits
IP Rating (IP20-IP67)Protection against solids/liquids ingress

5. Application Fields

  • Consumer Electronics: Desktop PCs, printers, home appliances
  • Industrial Automation: PLC cabinets, motor drives, robotics
  • Medical Equipment: Ultrasound machines, ventilators, lab analyzers
  • Data Centers: Server racks, PDU units, UPS systems
  • Renewable Energy: Solar inverters, wind turbine controllers

6. Leading Manufacturers and Products

ManufacturerRepresentative Product
TE ConnectivityPower-Entry Modules with integrated filters
Amphenol CorporationSeries 1300 IEC C13 inlets
Molex IncorporatedMini-Fit Jr. power entry systems
Phoenix ContactTRABTECH power entry solutions

7. Selection Guidelines

Key consideration factors:

  1. Electrical Requirements: Match voltage/current ratings with system needs
  2. Environmental Conditions: Consider temperature, humidity, and vibration
  3. Certification Standards: UL/CSA, IEC 60320, medical 60601-1 compliance
  4. Mechanical Durability: Minimum 10,000 mating cycles for industrial use
  5. Space Constraints: Panel cutout dimensions and PCB footprint
  6. Protection Features: Surge suppression, overcurrent protection integration

8. Industry Trends

Emerging developments include:

  • Miniaturization: 30% size reduction in IEC connectors for portable devices
  • High-Power Density: 600V/100A modules for EV charging infrastructure
  • Smart Connectivity: Integrated power-line communication (PLC) capabilities
  • Eco-friendly Materials: Halogen-free thermoplastics adoption (growing at 15% CAGR)
  • Modular Designs: Hot-swappable power entry systems for 24/7 operations
RFQ BOM Call Skype Email
Top