Heavy Duty Connectors - Frames

Image Part Number Description / PDF Quantity Rfq
09140160313SP

09140160313SP

HARTING

FRAME HINGED SZ16B FOR 4MOD

0

1682180000

1682180000

Weidmuller

FRAME FIXED MALE SZ3 FOR 2MOD

0

09400169911

09400169911

HARTING

16 HPR EASYCON FRAME FOR 3 X HC3

12

09400229902

09400229902

HARTING

22 HPR SLIM FRAME FOR 4 HC MODUL

0

09140240304

09140240304

HARTING

FRAME HINGED SZ24B FOR 6MOD

0

C146P24005G8

C146P24005G8

Tuchel / Amphenol

FRAME

0

T2070244201-000

T2070244201-000

TE Connectivity AMP Connectors

T2070244201-000

0

0936010539

0936010539

Woodhead - Molex

FRAME A-B FOR 2 MODULES SIZE 6B

0

09140240315

09140240315

HARTING

24B MODULAR HINGED FRAME A-F (FO

0

5008090010

5008090010

Woodhead - Molex

MINI ROBOT CONN REC SHELL ASSY 4

0

09110009908

09110009908

HARTING

POTENTIAL EQUALISATION FEMALE CO

0

C146P10005G8

C146P10005G8

Tuchel / Amphenol

FRAME

0

1607790

1607790

Phoenix Contact

FRAME PANEL MOUNT SZ4 FOR 5MOD

0

09400249932

09400249932

HARTING

24 HPR EASYCON FRAME FOR 8 MODUL

0

09140160315

09140160315

HARTING

FRAME HINGED SZ16B FOR 4MOD

0

0936050029

0936050029

Woodhead - Molex

DOCKING FRAME 24B

0

C146S10005G8

C146S10005G8

Tuchel / Amphenol

FRAME

0

T2079104201-000

T2079104201-000

TE Connectivity AMP Connectors

H10A-T1-F

0

T2071244101-000

T2071244101-000

TE Connectivity AMP Connectors

H24BP-T6-M DOCKING FRAME_FLOATIN

0

09400229901

09400229901

HARTING

22 HPR SLIM FRAME FOR 4 HC MODUL

0

Heavy Duty Connectors - Frames

1. Overview

Heavy Duty Connectors - Frames are robust mechanical structures designed to support and protect high-current or high-voltage electrical connections in demanding environments. These frames serve as critical components in industrial systems, ensuring reliable power transmission and signal integrity while withstanding mechanical stress, temperature extremes, and environmental contaminants. Their importance spans across automation, energy infrastructure, and transportation sectors where failure prevention is paramount.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Modular Frame SystemsCustomizable slot configurations, tool-less assemblyAutomated production lines
Panel Mount FramesFront-access design, integrated strain reliefControl cabinets in chemical plants
Weatherproof FramesIP67+ sealing, corrosion-resistant coatingsOutdoor power distribution units
High-Voltage FramesExtended creepage distances, arc-resistant materialsRailway traction systems

3. Structure and Components

Typical frames consist of: - Aluminum Alloy Housing: Provides structural integrity with weight efficiency - Copper Alloy Conductors: Ensures low-resistance electrical paths ( 98% conductivity) - Polyamide Insulation: Maintains dielectric strength up to 8kV - Mechanical Locking System: Anti-vibration latches meeting MIL-STD-810G - Thermal Management Fins: Dissipates heat at current loads >200A

4. Key Technical Specifications

ParameterValue RangeImportance
Current Rating100-5000ADetermines power transmission capacity
Voltage RangeAC 50V-1500V / DC 50V-2000VSafety and insulation requirements
IP RatingIP20-IP69KEnvironmental protection level
Contact Resistance 0.5m Influences energy efficiency
Operating Temperature-40 C to +150 CMaterial stability indicator

5. Application Fields

  • Industrial Automation: Robotic welding systems, CNC machine tooling
  • Renewable Energy: Wind turbine converters, solar inverter arrays
  • Transportation: Electric vehicle charging stations, locomotive power systems
  • Heavy Machinery: Mining equipment control panels, construction vehicle hydraulics

6. Leading Manufacturers and Products

ManufacturerKey Product SeriesTechnical Highlights
TE ConnectivityDEUTSCH HD Frame Series1500V isolation, -55 C cold resistance
Amphenol IndustrialPowerlok HD Frames3000A capacity, quick-mate design
Phoenix ContactHeavycon SystemModular hybrid power/signal integration

7. Selection Recommendations

Key considerations include: - Electrical Requirements: Match current/voltage ratings with system specifications - Environmental Factors: Consider humidity, vibration, and chemical exposure - Compliance Standards: UL 1977, IEC 60998, or industry-specific certifications - Future Expansion: Select modular designs for scalability - Cost Analysis: Balance upfront investment vs. lifecycle maintenance costs

Example: For offshore wind turbine applications, specify IP68 frames with electroless nickel plating and 1500V insulation to withstand saltwater corrosion and high-voltage demands.

8. Industry Trends

Emerging developments include: - Miniaturization with enhanced current density (40% size reduction by 2027) - Smart frames integrating IoT sensors for predictive maintenance - Adoption of graphene-enhanced composites for thermal management - Increased demand for 1500V+ DC compatible designs in renewable energy - Standardization initiatives for cross-manufacturer interoperability (IEC 61984 amendments)

RFQ BOM Call Skype Email