Heavy Duty Connectors - Frames

Image Part Number Description / PDF Quantity Rfq
5008090000

5008090000

Woodhead - Molex

FRAME PANEL MOUNTING TYPE A

79

09110009971

09110009971

HARTING

FRAME FIXED SZ6B FOR 1MOD

10

1103250-4

1103250-4

TE Connectivity AMP Connectors

FRAME FIXED SZ6 FOR 4MOD

0

09140060371

09140060371

HARTING

6B MODULAR HINGED FRAME PLUS (SP

91

09300241702

09300241702

HARTING

HAN 24B DOCKING FRAME F. 2XHC650

24

C146S16001G8

C146S16001G8

Tuchel / Amphenol

FRAME FIXED FMALE SZE16 FOR 5MOD

35

1853007

1853007

Phoenix Contact

FRAME PANEL MOUNTING FOR 5MOD

1

09140240311

09140240311

HARTING

FRAME FIXED SZ24B FOR 6MOD

0

C146P10001G8

C146P10001G8

Tuchel / Amphenol

FRAME FIXED MALE SZE10 FOR 3MOD

0

0936010556

0936010556

Woodhead - Molex

FRAME A-D FOR 4 MODULES SIZE 16B

0

09400489809

09400489809

HARTING

FRAME FIXED MALE FOR 4MOD

6

09140060361

09140060361

HARTING

6B MODULAR HINGED FRAME PLUS (SP

230

C146S06001G8

C146S06001G8

Tuchel / Amphenol

FRAME FIXED FEMALE SZE6 FOR 2MOD

28

09110009938

09110009938

HARTING

FRAME FIXED FEMALE FOR 4MOD

0

11006000301

11006000301

HARTING

FRAME ASSEMBLY FOR 4MOD

6

09140161721

09140161721

HARTING

SLIDING FRAME HAN 16B, FLOATING

100

44423238

44423238

LAPP

MODULE FRAME MH-16 M 4SLOTS HB16

40

1110960-1

1110960-1

TE Connectivity AMP Connectors

FRAME FIXED MALE SZ8 FOR 2 MOD

5

C146S10002G8

C146S10002G8

Tuchel / Amphenol

FRAME FIXED FMALE SZE10 FOR 3MOD

0

09400249911

09400249911

HARTING

FRAME ASSEMBLY MALE FOR 3MOD

10

Heavy Duty Connectors - Frames

1. Overview

Heavy Duty Connectors - Frames are robust mechanical structures designed to support and protect high-current or high-voltage electrical connections in demanding environments. These frames serve as critical components in industrial systems, ensuring reliable power transmission and signal integrity while withstanding mechanical stress, temperature extremes, and environmental contaminants. Their importance spans across automation, energy infrastructure, and transportation sectors where failure prevention is paramount.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Modular Frame SystemsCustomizable slot configurations, tool-less assemblyAutomated production lines
Panel Mount FramesFront-access design, integrated strain reliefControl cabinets in chemical plants
Weatherproof FramesIP67+ sealing, corrosion-resistant coatingsOutdoor power distribution units
High-Voltage FramesExtended creepage distances, arc-resistant materialsRailway traction systems

3. Structure and Components

Typical frames consist of: - Aluminum Alloy Housing: Provides structural integrity with weight efficiency - Copper Alloy Conductors: Ensures low-resistance electrical paths ( 98% conductivity) - Polyamide Insulation: Maintains dielectric strength up to 8kV - Mechanical Locking System: Anti-vibration latches meeting MIL-STD-810G - Thermal Management Fins: Dissipates heat at current loads >200A

4. Key Technical Specifications

ParameterValue RangeImportance
Current Rating100-5000ADetermines power transmission capacity
Voltage RangeAC 50V-1500V / DC 50V-2000VSafety and insulation requirements
IP RatingIP20-IP69KEnvironmental protection level
Contact Resistance 0.5m Influences energy efficiency
Operating Temperature-40 C to +150 CMaterial stability indicator

5. Application Fields

  • Industrial Automation: Robotic welding systems, CNC machine tooling
  • Renewable Energy: Wind turbine converters, solar inverter arrays
  • Transportation: Electric vehicle charging stations, locomotive power systems
  • Heavy Machinery: Mining equipment control panels, construction vehicle hydraulics

6. Leading Manufacturers and Products

ManufacturerKey Product SeriesTechnical Highlights
TE ConnectivityDEUTSCH HD Frame Series1500V isolation, -55 C cold resistance
Amphenol IndustrialPowerlok HD Frames3000A capacity, quick-mate design
Phoenix ContactHeavycon SystemModular hybrid power/signal integration

7. Selection Recommendations

Key considerations include: - Electrical Requirements: Match current/voltage ratings with system specifications - Environmental Factors: Consider humidity, vibration, and chemical exposure - Compliance Standards: UL 1977, IEC 60998, or industry-specific certifications - Future Expansion: Select modular designs for scalability - Cost Analysis: Balance upfront investment vs. lifecycle maintenance costs

Example: For offshore wind turbine applications, specify IP68 frames with electroless nickel plating and 1500V insulation to withstand saltwater corrosion and high-voltage demands.

8. Industry Trends

Emerging developments include: - Miniaturization with enhanced current density (40% size reduction by 2027) - Smart frames integrating IoT sensors for predictive maintenance - Adoption of graphene-enhanced composites for thermal management - Increased demand for 1500V+ DC compatible designs in renewable energy - Standardization initiatives for cross-manufacturer interoperability (IEC 61984 amendments)

RFQ BOM Call Skype Email
Top