Heavy Duty Connectors - Accessories

Image Part Number Description / PDF Quantity Rfq
1415760

1415760

Phoenix Contact

HEAVYPORT BASE W/RJ45 FEMALE

261

1415778

1415778

Phoenix Contact

HEAVYPORT W/120V OUTLT 2 9P DSUB

23

1411351

1411351

Phoenix Contact

HC-D-G-M25-PLRBK

5100

1644083

1644083

Phoenix Contact

CABLE FEED-THROUGH SLEEVES

186

1412885

1412885

Phoenix Contact

SINGLE LOCKING LATCH FOR B24 HOU

0

1415779

1415779

Phoenix Contact

HVYPRT W/2 USB A FML & 120V OTL

1013

1415783

1415783

Phoenix Contact

HEAVYPORT BASE W/120V OUTLET

1012

1853764

1853764

Phoenix Contact

HALF SCREW CONNECTION PG16

254

1414265

1414265

Phoenix Contact

ADAPTER ALUMINUM

1

1411441

1411441

Phoenix Contact

HC-B-G-M40-EC-AL

656

1646007

1646007

Phoenix Contact

CABLE RELIEF 21MM

1868

1424374

1424374

Phoenix Contact

PROTECTIVE COVER SZD15 SNGL LOCK

0

1409804

1409804

Phoenix Contact

HC-B 10-TMS-EEE-PR-DI

0

1885428

1885428

Phoenix Contact

CABLE GLAND

0

1408203

1408203

Phoenix Contact

ORING REPLACEMENT

0

1646201

1646201

Phoenix Contact

CABLE RELIEF 30MM

0

1414663

1414663

Phoenix Contact

CABLE GLAND

0

1414262

1414262

Phoenix Contact

ADAPTER ALUMINUM

17

1407694

1407694

Phoenix Contact

HC-B16-BC-HI-PLBK

0

1411479

1411479

Phoenix Contact

PROFILE GASKET FOR HEAVYCON EVO

0

Heavy Duty Connectors - Accessories

1. Overview

Heavy Duty Connectors (HDC) and accessories are industrial-grade electrical components designed to establish secure and reliable connections in harsh environments. They support high current, voltage, and mechanical stress tolerance, enabling safe power/data transmission in critical systems. These connectors are essential in modern infrastructure, including renewable energy systems, smart grids, and industrial automation, where failure prevention and operational continuity are paramount.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Industrial Circular ConnectorsRobust metal/plastic housing, IP65-IP69K protection, threaded couplingFactory automation equipment, robotics
Power Distribution ConnectorsHigh-current capacity (up to 1000A), multi-pole designWind turbines, data center UPS systems
Railway ConnectorsVibration-resistant, EMI shielding, fire-retardant materialsHigh-speed trains, subway systems
Hydraulic/Pneumatic ConnectorsCombined electrical-fluidic interfaces, leak-proof sealingMining equipment, construction machinery
AccessoriesCable glands, panel mount adapters, contact insertsCustom system integration

3. Structure and Components

A typical HDC assembly comprises:
- Housing: Thermoplastic (PA66) or die-cast metal (aluminum alloy) with anti-UV treatment
- Contact System: Silver-plated copper alloy contacts with self-cleaning design
- Insulation: High-temperature resistant PA or PPS materials (180 C rating)
- Retention Mechanism: Threaded, bayonet, or push-pull locking systems
- Sealing: EPDM rubber gaskets for IP67 protection

4. Key Technical Specifications

ParameterImportance
Rated Current (16-2000A)Determines power transmission capacity
Dielectric Withstanding Voltage (1000-8000V)Ensures electrical safety under overvoltage
Contact Resistance ( 0.5m )Minimizes energy loss and thermal rise
Mechanical Durability (5000-20000 mating cycles)Long-term reliability indicator
Operating Temperature (-40 C to +150 C)Environmental adaptability
Vibration Resistance (10G-50G)Critical for mobile/transport applications

5. Application Fields

Key industries include:
- Energy: Solar inverters, offshore wind turbines
- Transportation: Electric vehicle charging stations, locomotive systems
- Manufacturing: CNC machines, automated guided vehicles (AGVs)
- Infrastructure: Smart grid switchgear, emergency power systems
- Special Cases: Explosion-proof connectors for petrochemical plants

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
TE ConnectivityDEUTSCH HC Series600A capacity, aerospace-grade reliability
Amphenol IndustrialDuramax MaxGuardIP69K rated, corrosion-resistant marine grade
Phoenix ContactHeavycon SystemModular design with hybrid power/signal integration
Delphi Connection SystemsWeatherGuard HV1500V DC rating for photovoltaic applications

7. Selection Recommendations

Key considerations:
1. Calculate maximum current/voltage with 20% safety margin
2. Match IP rating to environmental conditions (e.g., IP67 for outdoor use)
3. Consider mating cycle requirements for maintenance frequency
4. Verify material compatibility for chemical exposure
5. Check standard certifications (IEC 61984, UL 1977)
Case Example: For offshore wind turbine generator connection: Select IP68-rated connector with 1500V insulation and salt spray resistance >1000h.

8. Industry Trends

Emerging trends include:
- Miniaturization with increased power density (e.g., 30% size reduction by 2025)
- Integrated smart sensors for predictive maintenance
- Adoption of composite materials for weight reduction (-40% vs. metal)
- Development of hydrogen-compatible connectors for fuel cell systems
- Growth in hybrid connectors combining power, data, and fluid transmission

RFQ BOM Call Skype Email
Top