Coaxial Connectors (RF) - Terminators

Image Part Number Description / PDF Quantity Rfq
32S15R-1.0E3

32S15R-1.0E3

Rosenberger

TERMINATOR SMA PLUG 50 OHM

107

53S15R-005N3

53S15R-005N3

Rosenberger

N TYPE TERMINATOR

0

202120

202120

Connex (Amphenol RF)

CONN TERMINATOR JACK BNC 50 OHM

94

CT3366

CT3366

Cal Test Electronics

CONN TERMINATOR JACK BNC 50 OHM

0

J01444A3000

J01444A3000

Telegärtner

4.3-10 TERM PLUG PUSH 7.5GHZ 2W

0

SF8012-6101

SF8012-6101

SV Microwave (Amphenol SV Microwave)

CONN TERMINATOR PLUG SMP 50 OHM

0

132360RP

132360RP

Connex (Amphenol RF)

CONN TERMINATR PLUG RP-SMA 50OHM

838

142-9003-201

142-9003-201

Vitelec / Cinch Connectivity Solutions

SMA STRAIGHT TERMINATION

0

142197

142197

Connex (Amphenol RF)

CONN TERMINATOR

204

VBT75

VBT75

Vitelec / Cinch Connectivity Solutions

CONN TERMINATOR PLUG BNC 75OHM

4

000-46650-93RFX

000-46650-93RFX

Connex (Amphenol RF)

CONN TERMINATOR PLUG BNC 93OHM

30

202103

202103

Connex (Amphenol RF)

CONN TERMINATOR PLUG BNC 50OHM

4451

TNGMFL1-1-78

TNGMFL1-1-78

Vitelec / Cinch Connectivity Solutions

CONN TERMINATOR JACK TRS 78OHM

3

SF8016-6402

SF8016-6402

SV Microwave (Amphenol SV Microwave)

CONN TERMINATR JACK 2.4MM 50 OHM

0

202117

202117

Connex (Amphenol RF)

CONN TERMINATOR PLUG TNC 50OHM

384

202110

202110

Connex (Amphenol RF)

CONN TERMINATOR JACK N 50OHM

0

D-607-09CS764

D-607-09CS764

TE Connectivity Aerospace Defense and Marine

CONN TERMINATOR

229

CT2944C-50

CT2944C-50

Cal Test Electronics

CONN TERMINATOR ADAPT BNC 50 OHM

33

5221629-2

5221629-2

TE Connectivity AMP Connectors

CONN TERMINATOR PLUG BNC 75OHM

0

32K15R-001E3

32K15R-001E3

Rosenberger

TERMINATOR SMA JACK 50 OHM

93

Coaxial Connectors (RF) - Terminators

1. Overview

RF coaxial connector terminators are passive components designed to match the characteristic impedance of coaxial cables and systems, preventing signal reflections that cause interference and power loss. They are critical in maintaining signal integrity in high-frequency applications. These terminators absorb transmitted energy, ensuring optimal performance in RF circuits, test systems, and communication networks.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
N-Type Terminator50 impedance, threaded coupling, weatherproof designCellular base stations, microwave systems
BNC TerminatorQuick-connect bayonet style, 50/75 optionsTest equipment, video systems
SMA TerminatorSubminiature threaded design, 0-18 GHz frequency rangeWireless communication modules, aerospace systems
TNC TerminatorThreaded BNC variant, vibration-resistantMilitary radios, mobile networks
F-Type Terminator75 screw-on design for CATV systemsCable TV modems, satellite receivers

3. Structure and Components

Typical terminators consist of: - Outer conductor (copper/aluminum) for shielding - Dielectric material (PTFE/ceramic) maintaining impedance - Center conductor termination resistor (precision chip) - Threaded/snap-fit coupling mechanism - Corrosion-resistant plating (nickel/gold)

4. Key Technical Specifications

ParameterDescriptionImportance
Impedance ( )Standard 50 /75 matchingEnsures minimal signal reflection
Frequency RangeDC-18GHz for SMA, DC-11GHz for N-TypeDefines operational bandwidth
VSWR0.1-2.0:1 ratioMeasures impedance matching quality
Power Handling10W-500W average powerDetermines thermal stability
Environmental Rating-55 C to +165 C operating temp, IP67Guarantees reliability in harsh conditions

5. Application Fields

  • Telecommunications: 5G base stations, fiber optic nodes
  • Broadcast: TV transmission equipment, satellite systems
  • Test & Measurement: Spectrum analyzers, signal generators
  • Aerospace: Avionics, radar systems
  • Industrial: Medical imaging equipment (MRI), IoT devices

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Amphenol901-5066 SMA Terminator18GHz, 50 , VSWR 1.1:1
TE ConnectivityN-Term-50-12 N-TypeIP68 rated, 500W power handling
Keysight Technologies8120-0033 BNC Terminator50 precision load for lab testing
Rosenberger806 343S TNC TerminatorCorrosion-proof, -40 C to +125 C

7. Selection Guidelines

Key considerations: - Impedance match with system (50 vs 75 ) - Frequency requirements (check cutoff points) - Environmental conditions (temperature, moisture) - Connection type (threaded vs quick-connect) - Power dissipation needs (high-power applications require larger terminators) - Industry standards (MIL-STD, IEC, EIA)

8. Industry Trends

Current developments include: - Miniaturization for 5G mmWave applications (2.4mm, 1.85mm connectors) - Enhanced thermal management for high-power 5G arrays - Standardization of 75 terminators for automotive radar (76-81GHz) - Adoption of RoHS-compliant materials (lead-free plating) - Integration with smart monitoring systems for network health diagnostics - Development of reusable terminators for lab environments

RFQ BOM Call Skype Email
Top