Inrush Current Limiters (ICL)

Image Part Number Description / PDF Quantity Rfq
SL22 0R516

SL22 0R516

Ametherm

ICL 500 MOHM 25% 16A 22MM

2193

SL22 2R510-B

SL22 2R510-B

Ametherm

ICL 2.5 OHM 20% 10A 22MM

0

SL22 40005

SL22 40005

Ametherm

ICL 40 OHM 20% 5A 22MM

2557

SL32 0R536

SL32 0R536

Ametherm

ICL 500 MOHM 20% 36A 31MM

0

SL22 16004-A

SL22 16004-A

Ametherm

ICL 16 OHM 20% 4A 22MM

0

SG240

SG240

Ametherm

ICL 40 OHM 15% 2A 15.88MM

3149

SL12 25003-B

SL12 25003-B

Ametherm

ICL 25 OHM 15% 3A 13MM

0

MS32 0R536-B

MS32 0R536-B

Ametherm

ICL 500 MOHM 25% 36A 31MM

6

AS35 20010

AS35 20010

Ametherm

ICL 20 OHM 25% 10A 36MM

34

SG40

SG40

Ametherm

ICL 10 OHM 20% 8A 22.86MM

791

MS32 1R036

MS32 1R036

Ametherm

ICL 1 OHM 25% 36A 31MM

0

SL15 5R007-A

SL15 5R007-A

Ametherm

ICL 5 OHM 20% 7A 16MM

0

SL18 7R005

SL18 7R005

Ametherm

ICL 7 OHM 20% 5A 19MM

0

SG302

SG302

Ametherm

ICL 2 OHM 15% 18A 22.86MM

0

SL08 7R002-A

SL08 7R002-A

Ametherm

ICL 7 OHM 20% 2A 8MM

0

SG416

SG416

Ametherm

ICL 1.3 OHM 25% 8A 13.97MM

0

SL22 2R508-B

SL22 2R508-B

Ametherm

ICL 2.5 OHM 20% 8A 22MM

0

MS15 15004

MS15 15004

Ametherm

ICL 15 OHM 25% 4.5A 15MM

0

SL22 10007-B

SL22 10007-B

Ametherm

ICL 10 OHM 20% 7A 22MM

0

SL12 22101-A

SL12 22101-A

Ametherm

ICL 220 OHM 20% 1A 13MM

108

Inrush Current Limiters (ICL)

1. Overview

Inrush Current Limiters (ICL) are electronic components designed to suppress peak currents during device startup, protecting circuits from thermal and electrical stress. These transient currents, often 10-100 times higher than steady-state levels, occur in capacitive or inductive loads like power supplies, motors, and transformers. Modern electronics increasingly rely on ICLs to ensure system reliability, comply with safety standards, and extend product lifespans.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
NTC Thermistor ICLResistance decreases with temperature rise, self-resetting capabilitySwitching power supplies, LED drivers
PTC Thermistor ICLResistance increases with temperature, latching protectionMotor start circuits, battery management systems
Active ICLElectronic control using MOSFETs/IGBTs with precise timingHigh-precision industrial equipment
Hybrid ICLCombines passive and active elements for optimized performanceElectric vehicle charging stations

3. Structure & Composition

ICLs typically consist of three key elements:

  • Sensing Element: Thermally responsive material (e.g., NTC ceramic) or semiconductor junctions
  • Conductive Path: Silver/palladium electrodes in thermistors or MOSFET channels in active devices
  • Encapsulation: Epoxy or ceramic coatings for environmental protection

Active ICLs additionally integrate control ICs, gate drivers, and heat dissipation structures.

4. Key Technical Specifications

ParameterDescriptionImportance
Maximum Steady-State Current (Imax)Rated operational current after inrush suppressionDetermines continuous load capacity
Response Time (tresponse)Time to activate current limiting functionProtects against fast transient events
Clamping Voltage (Vclamp)Maximum voltage during limiting operationPrevents downstream component damage
Operating Temperature RangeFunctional temperature limitsEnsures reliability in extreme environments
Energy Absorption (I t)Total energy handling capabilityDefines survival under fault conditions

5. Application Fields

Major industries utilizing ICLs include:

  • Consumer Electronics: Power adapters, HVAC systems
  • Industrial: Variable frequency drives, welding machines
  • Automotive: EV charging stations, onboard chargers
  • Medical: MRI power systems, patient monitors

Typical case: NTC ICLs reduce 50A startup surges to 5A in 500W switching power supplies.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
TDK CorporationB59xxx SeriesHigh-reliability NTCs for automotive applications
LittelfusePTCLxxx SeriesAEC-Q100 qualified PTC devices
Bel Fuse0Zxxx SeriesMulti-layer ceramic thermistors
EPCOS (TDK)B25xxx SeriesHybrid ICLs with integrated sensors

7. Selection Guidelines

Critical factors for proper ICL selection:

  • Match Imax with system steady-state requirements (+20% margin)
  • Verify Vrated exceeds peak AC voltage by 50%
  • Consider ambient temperature effects on performance
  • Evaluate reset time for thermistor-based solutions
  • For active ICLs: Confirm compatibility with control signals

Example: A 240VAC motor drive requires an ICL with 15A Imax and 300Vclamp.

8. Industry Trends

Emerging developments include:

  • Miniaturization: 0603-sized active ICLs for mobile devices
  • Wide bandgap integration: SiC/GaN-based hybrid devices
  • Smart ICLs: Embedded current monitoring and diagnostics
  • Material innovation: Graphene-enhanced thermistors

Market growth driven by EV charging infrastructure and renewable energy systems, projected at 7.2% CAGR through 2027.