Inrush Current Limiters (ICL)

Image Part Number Description / PDF Quantity Rfq
SG100

SG100

Ametherm

ICL 1 OHM 15% 20A 22.86MM

2455

SL15 30004

SL15 30004

Ametherm

ICL 30 OHM 20% 4A 15MM

231

SL12-1R308-A

SL12-1R308-A

Ametherm

ICL 1.3 OHM 20% 8A 13MM

201

SL22 12103-A

SL22 12103-A

Ametherm

ICL 120 OHM 25% 3A 22MM

0

SL12 22101-B

SL12 22101-B

Ametherm

ICL 220 OHM 20% 1A 13MM

0

SL22 10005-B

SL22 10005-B

Ametherm

ICL 10 OHM 20% 5A 22MM

0

MS32 50006

MS32 50006

Ametherm

ICL 50 OHM 25% 6A 31MM

0

AS32 2R025

AS32 2R025

Ametherm

ICL 2 OHM 25% 25A 30MM

7006

SL15 47003-A

SL15 47003-A

Ametherm

ICL 47 OHM 20% 3A 16MM

0

SL22 14005-A

SL22 14005-A

Ametherm

ICL 14 OHM 25% 5A 22MM

0

MS22 12102-B

MS22 12102-B

Ametherm

ICL 120 OHM 25% 2A 23MM

0

MS22 12104-A

MS22 12104-A

Ametherm

ICL 120 OHM 25% 4A 23MM

0

SL22 12102-A

SL22 12102-A

Ametherm

ICL 120 OHM 25% 2A 22MM

0

SL10 12101-B

SL10 12101-B

Ametherm

ICL 120 OHM 20% 1A 10MM

0

AS32 1R030

AS32 1R030

Ametherm

ICL 1 OHM 25% 30A 30MM

42

SL12 10005-B

SL12 10005-B

Ametherm

ICL 10 OHM 20% 5A 13MM

0

SL05 60001

SL05 60001

Ametherm

ICL 60 OHM 15% 1A 5.5MM

749

SL32 1R036-B

SL32 1R036-B

Ametherm

ICL 1 OHM 20% 36A 31MM

813

MS15 15004-B

MS15 15004-B

Ametherm

ICL 15 OHM 25% 4.5A 15MM

0

SL22 5R012-AT

SL22 5R012-AT

Ametherm

ICL 5 OHM 20% 12A 22MM

0

Inrush Current Limiters (ICL)

1. Overview

Inrush Current Limiters (ICL) are electronic components designed to suppress peak currents during device startup, protecting circuits from thermal and electrical stress. These transient currents, often 10-100 times higher than steady-state levels, occur in capacitive or inductive loads like power supplies, motors, and transformers. Modern electronics increasingly rely on ICLs to ensure system reliability, comply with safety standards, and extend product lifespans.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
NTC Thermistor ICLResistance decreases with temperature rise, self-resetting capabilitySwitching power supplies, LED drivers
PTC Thermistor ICLResistance increases with temperature, latching protectionMotor start circuits, battery management systems
Active ICLElectronic control using MOSFETs/IGBTs with precise timingHigh-precision industrial equipment
Hybrid ICLCombines passive and active elements for optimized performanceElectric vehicle charging stations

3. Structure & Composition

ICLs typically consist of three key elements:

  • Sensing Element: Thermally responsive material (e.g., NTC ceramic) or semiconductor junctions
  • Conductive Path: Silver/palladium electrodes in thermistors or MOSFET channels in active devices
  • Encapsulation: Epoxy or ceramic coatings for environmental protection

Active ICLs additionally integrate control ICs, gate drivers, and heat dissipation structures.

4. Key Technical Specifications

ParameterDescriptionImportance
Maximum Steady-State Current (Imax)Rated operational current after inrush suppressionDetermines continuous load capacity
Response Time (tresponse)Time to activate current limiting functionProtects against fast transient events
Clamping Voltage (Vclamp)Maximum voltage during limiting operationPrevents downstream component damage
Operating Temperature RangeFunctional temperature limitsEnsures reliability in extreme environments
Energy Absorption (I t)Total energy handling capabilityDefines survival under fault conditions

5. Application Fields

Major industries utilizing ICLs include:

  • Consumer Electronics: Power adapters, HVAC systems
  • Industrial: Variable frequency drives, welding machines
  • Automotive: EV charging stations, onboard chargers
  • Medical: MRI power systems, patient monitors

Typical case: NTC ICLs reduce 50A startup surges to 5A in 500W switching power supplies.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
TDK CorporationB59xxx SeriesHigh-reliability NTCs for automotive applications
LittelfusePTCLxxx SeriesAEC-Q100 qualified PTC devices
Bel Fuse0Zxxx SeriesMulti-layer ceramic thermistors
EPCOS (TDK)B25xxx SeriesHybrid ICLs with integrated sensors

7. Selection Guidelines

Critical factors for proper ICL selection:

  • Match Imax with system steady-state requirements (+20% margin)
  • Verify Vrated exceeds peak AC voltage by 50%
  • Consider ambient temperature effects on performance
  • Evaluate reset time for thermistor-based solutions
  • For active ICLs: Confirm compatibility with control signals

Example: A 240VAC motor drive requires an ICL with 15A Imax and 300Vclamp.

8. Industry Trends

Emerging developments include:

  • Miniaturization: 0603-sized active ICLs for mobile devices
  • Wide bandgap integration: SiC/GaN-based hybrid devices
  • Smart ICLs: Embedded current monitoring and diagnostics
  • Material innovation: Graphene-enhanced thermistors

Market growth driven by EV charging infrastructure and renewable energy systems, projected at 7.2% CAGR through 2027.