Inrush Current Limiters (ICL)

Image Part Number Description / PDF Quantity Rfq
MF72-060D5

MF72-060D5

Cantherm

ICL 60 OHM 20% 300MA 7MM

12787

MF72-047D15-LI

MF72-047D15-LI

Cantherm

ICL 47 OHM 20% 3A 27.5MM

2

MF72-010D25

MF72-010D25

Cantherm

ICL 10 OHM 20% 7A 27.5MM

254

MF72-016D20

MF72-016D20

Cantherm

ICL 16 OHM 20% 5A 22.5MM

300

MF72-012D13

MF72-012D13

Cantherm

ICL 12 OHM 20% 3A 15.5MM

277

MF73T-1 10/8

MF73T-1 10/8

Cantherm

ICL 10 OHM 20% 8A 20MM

72

MF72-008D13

MF72-008D13

Cantherm

ICL 8 OHM 20% 4A 15.5MM

310

MF73T-1 1/20

MF73T-1 1/20

Cantherm

ICL 1 OHM 20% 20A 25MM

36

MF72-003D15

MF72-003D15

Cantherm

ICL 3 OHM 20% 7A 17.5MM

479

MF72-003D11

MF72-003D11

Cantherm

ICL 3 OHM 20% 5A 13MM

4368

MF73T-1 5/14

MF73T-1 5/14

Cantherm

ICL 5 OHM 20% 14A 25MM

0

MF73T-1 1/32

MF73T-1 1/32

Cantherm

ICL 1 OHM 20% 32A 35MM

23

MF72-010D7

MF72-010D7

Cantherm

ICL 10 OHM 20% 1A 9MM

0

MF73T-1 1/30

MF73T-1 1/30

Cantherm

ICL 1 OHM 20% 30A 30MM

173

MF72-005D13

MF72-005D13

Cantherm

ICL 5 OHM 20% 5A 15.5MM

2040

MF72-030D13

MF72-030D13

Cantherm

ICL 30 OHM 20% 2.5A 15.5MM

424

MF73T-1 10/19

MF73T-1 10/19

Cantherm

ICL 10 OHM 20% 19A 40MM

30

MF72-015D15

MF72-015D15

Cantherm

ICL 15 OHM 20% 4A 17.5MM

0

MF72-022D11

MF72-022D11

Cantherm

ICL 22 OHM 20% 2A 13MM

2367

MF72-060D9

MF72-060D9

Cantherm

ICL 60 OHM 20% 800MA 11MM

23667

Inrush Current Limiters (ICL)

1. Overview

Inrush Current Limiters (ICL) are electronic components designed to suppress peak currents during device startup, protecting circuits from thermal and electrical stress. These transient currents, often 10-100 times higher than steady-state levels, occur in capacitive or inductive loads like power supplies, motors, and transformers. Modern electronics increasingly rely on ICLs to ensure system reliability, comply with safety standards, and extend product lifespans.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
NTC Thermistor ICLResistance decreases with temperature rise, self-resetting capabilitySwitching power supplies, LED drivers
PTC Thermistor ICLResistance increases with temperature, latching protectionMotor start circuits, battery management systems
Active ICLElectronic control using MOSFETs/IGBTs with precise timingHigh-precision industrial equipment
Hybrid ICLCombines passive and active elements for optimized performanceElectric vehicle charging stations

3. Structure & Composition

ICLs typically consist of three key elements:

  • Sensing Element: Thermally responsive material (e.g., NTC ceramic) or semiconductor junctions
  • Conductive Path: Silver/palladium electrodes in thermistors or MOSFET channels in active devices
  • Encapsulation: Epoxy or ceramic coatings for environmental protection

Active ICLs additionally integrate control ICs, gate drivers, and heat dissipation structures.

4. Key Technical Specifications

ParameterDescriptionImportance
Maximum Steady-State Current (Imax)Rated operational current after inrush suppressionDetermines continuous load capacity
Response Time (tresponse)Time to activate current limiting functionProtects against fast transient events
Clamping Voltage (Vclamp)Maximum voltage during limiting operationPrevents downstream component damage
Operating Temperature RangeFunctional temperature limitsEnsures reliability in extreme environments
Energy Absorption (I t)Total energy handling capabilityDefines survival under fault conditions

5. Application Fields

Major industries utilizing ICLs include:

  • Consumer Electronics: Power adapters, HVAC systems
  • Industrial: Variable frequency drives, welding machines
  • Automotive: EV charging stations, onboard chargers
  • Medical: MRI power systems, patient monitors

Typical case: NTC ICLs reduce 50A startup surges to 5A in 500W switching power supplies.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
TDK CorporationB59xxx SeriesHigh-reliability NTCs for automotive applications
LittelfusePTCLxxx SeriesAEC-Q100 qualified PTC devices
Bel Fuse0Zxxx SeriesMulti-layer ceramic thermistors
EPCOS (TDK)B25xxx SeriesHybrid ICLs with integrated sensors

7. Selection Guidelines

Critical factors for proper ICL selection:

  • Match Imax with system steady-state requirements (+20% margin)
  • Verify Vrated exceeds peak AC voltage by 50%
  • Consider ambient temperature effects on performance
  • Evaluate reset time for thermistor-based solutions
  • For active ICLs: Confirm compatibility with control signals

Example: A 240VAC motor drive requires an ICL with 15A Imax and 300Vclamp.

8. Industry Trends

Emerging developments include:

  • Miniaturization: 0603-sized active ICLs for mobile devices
  • Wide bandgap integration: SiC/GaN-based hybrid devices
  • Smart ICLs: Embedded current monitoring and diagnostics
  • Material innovation: Graphene-enhanced thermistors

Market growth driven by EV charging infrastructure and renewable energy systems, projected at 7.2% CAGR through 2027.