Inrush Current Limiters (ICL)

Image Part Number Description / PDF Quantity Rfq
SG332

SG332

Ametherm

ICL 5 OHM 20% 8A 15.24MM

0

SG320

SG320

Ametherm

ICL 16 OHM 25% 4A 19.05MM

0

SL1580003

SL1580003

Ametherm

ICL 80 OHM 25% 3A 15.5MM

37

B57236S200M54

B57236S200M54

TDK EPCOS

ICL 20 OHM 20% 2.8A 11.5MM

0

SL10 5R004

SL10 5R004

Ametherm

ICL 5 OHM 20% 4A 10MM

0

MF72-004D9-STRAIGHT

MF72-004D9-STRAIGHT

Cantherm

ICL 4 OHM 20% 3A

256

SL12 2R505

SL12 2R505

Ametherm

ICL 2.5 OHM 25% 5A 13MM

58

SG331

SG331

Ametherm

ICL 5 OHM 15% 7A 15.24MM

0

SL12 5R002

SL12 5R002

Ametherm

ICL 5 OHM 20% 2A 13MM

259

MF72-080D9-STRAIGHT

MF72-080D9-STRAIGHT

Cantherm

ICL 80 OHM 20%

0

SL18 0R712

SL18 0R712

Ametherm

ICL 700 MOHM 20% 12A 19MM

60

MM35 1R050-DIN

MM35 1R050-DIN

Ametherm

ICL 1 OHM 25% 50A 68MM

6

ST20001C

ST20001C

Wickmann / Littelfuse

ICL 20 OHM 20% 300MA 8.89MM

0

ST15004C

ST15004C

Wickmann / Littelfuse

ICL 15 OHM 20% 4A 19.56MM

0

ST5R004B

ST5R004B

Wickmann / Littelfuse

ICL 5 OHM 20% 4A 15.24MM

0

NTPA74R0LB1A0

NTPA74R0LB1A0

TOKO / Murata

ICL 4 OHM 15% 2.3A 7MM

0

ST5R008B

ST5R008B

Wickmann / Littelfuse

ICL 5 OHM 20% 8A 29.21MM

0

ST10005B

ST10005B

Wickmann / Littelfuse

ICL 10 OHM 20% 5A 19.05MM

0

ST2R503B

ST2R503B

Wickmann / Littelfuse

ICL 2.5 OHM 20% 3A 15.24MM

0

NTPA7160LBMB0

NTPA7160LBMB0

TOKO / Murata

ICL 16 OHM 15% 1.2A 7MM

0

Inrush Current Limiters (ICL)

1. Overview

Inrush Current Limiters (ICL) are electronic components designed to suppress peak currents during device startup, protecting circuits from thermal and electrical stress. These transient currents, often 10-100 times higher than steady-state levels, occur in capacitive or inductive loads like power supplies, motors, and transformers. Modern electronics increasingly rely on ICLs to ensure system reliability, comply with safety standards, and extend product lifespans.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
NTC Thermistor ICLResistance decreases with temperature rise, self-resetting capabilitySwitching power supplies, LED drivers
PTC Thermistor ICLResistance increases with temperature, latching protectionMotor start circuits, battery management systems
Active ICLElectronic control using MOSFETs/IGBTs with precise timingHigh-precision industrial equipment
Hybrid ICLCombines passive and active elements for optimized performanceElectric vehicle charging stations

3. Structure & Composition

ICLs typically consist of three key elements:

  • Sensing Element: Thermally responsive material (e.g., NTC ceramic) or semiconductor junctions
  • Conductive Path: Silver/palladium electrodes in thermistors or MOSFET channels in active devices
  • Encapsulation: Epoxy or ceramic coatings for environmental protection

Active ICLs additionally integrate control ICs, gate drivers, and heat dissipation structures.

4. Key Technical Specifications

ParameterDescriptionImportance
Maximum Steady-State Current (Imax)Rated operational current after inrush suppressionDetermines continuous load capacity
Response Time (tresponse)Time to activate current limiting functionProtects against fast transient events
Clamping Voltage (Vclamp)Maximum voltage during limiting operationPrevents downstream component damage
Operating Temperature RangeFunctional temperature limitsEnsures reliability in extreme environments
Energy Absorption (I t)Total energy handling capabilityDefines survival under fault conditions

5. Application Fields

Major industries utilizing ICLs include:

  • Consumer Electronics: Power adapters, HVAC systems
  • Industrial: Variable frequency drives, welding machines
  • Automotive: EV charging stations, onboard chargers
  • Medical: MRI power systems, patient monitors

Typical case: NTC ICLs reduce 50A startup surges to 5A in 500W switching power supplies.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
TDK CorporationB59xxx SeriesHigh-reliability NTCs for automotive applications
LittelfusePTCLxxx SeriesAEC-Q100 qualified PTC devices
Bel Fuse0Zxxx SeriesMulti-layer ceramic thermistors
EPCOS (TDK)B25xxx SeriesHybrid ICLs with integrated sensors

7. Selection Guidelines

Critical factors for proper ICL selection:

  • Match Imax with system steady-state requirements (+20% margin)
  • Verify Vrated exceeds peak AC voltage by 50%
  • Consider ambient temperature effects on performance
  • Evaluate reset time for thermistor-based solutions
  • For active ICLs: Confirm compatibility with control signals

Example: A 240VAC motor drive requires an ICL with 15A Imax and 300Vclamp.

8. Industry Trends

Emerging developments include:

  • Miniaturization: 0603-sized active ICLs for mobile devices
  • Wide bandgap integration: SiC/GaN-based hybrid devices
  • Smart ICLs: Embedded current monitoring and diagnostics
  • Material innovation: Graphene-enhanced thermistors

Market growth driven by EV charging infrastructure and renewable energy systems, projected at 7.2% CAGR through 2027.

RFQ BOM Call Skype Email
Top