Gas Discharge Tube Arresters (GDT)

Image Part Number Description / PDF Quantity Rfq
PMT825004

PMT825004

Wickmann / Littelfuse

GDT 250V 20KA 3 POLE TH

0

SL1021A450RS

SL1021A450RS

Wickmann / Littelfuse

GDT 450V 10KA 3 POLE TH

0

SL1011B075A

SL1011B075A

Wickmann / Littelfuse

GDT 75V 10KA 2 POLE THROUGH HOLE

0

PMT6090MS

PMT6090MS

Wickmann / Littelfuse

GDT 90V 5KA 3 POLE

0

SL1024A230R

SL1024A230R

Wickmann / Littelfuse

GDT 230V 10KA 3 POLE TH

0

SL1021A300RG

SL1021A300RG

Wickmann / Littelfuse

GDT 300V 10KA 3 POLE TH

0

SL1024A500R

SL1024A500R

Wickmann / Littelfuse

GDT 500V 10KA 3 POLE TH

0

GTCA28-351M-P15

GTCA28-351M-P15

Wickmann / Littelfuse

GDT 350V 15KA 2 POLE TH

0

SL1011A400A

SL1011A400A

Wickmann / Littelfuse

GDT 400V 5KA 2 POLE THROUGH HOLE

0

GTCN28-231M-P15-FS

GTCN28-231M-P15-FS

Wickmann / Littelfuse

GDT 230V 15KA 2 POLE

0

GTCR38-900M-Q10

GTCR38-900M-Q10

Wickmann / Littelfuse

GDT 90V 10KA 3 POLE THROUGH HOLE

0

GTCN28-601L-P05

GTCN28-601L-P05

Wickmann / Littelfuse

GDT 600V 5KA 2 POLE

0

SL1021A150RS

SL1021A150RS

Wickmann / Littelfuse

GDT 200V 10KA 3 POLE TH

0

SL1021A600RG

SL1021A600RG

Wickmann / Littelfuse

GDT 600V 10KA 3 POLE TH

0

GTCR36-351M-P05

GTCR36-351M-P05

Wickmann / Littelfuse

GDT 350V 5KA 3 POLE THROUGH HOLE

0

GTCA28-302M-P01

GTCA28-302M-P01

Wickmann / Littelfuse

GDT 3000V 1KA 2 POLE TH

0

GTCS35-750M-R05-RB-2

GTCS35-750M-R05-RB-2

Wickmann / Littelfuse

GDT 75V 5KA 3 POLE SURFACE MOUNT

0

GTCT37-351M-P10

GTCT37-351M-P10

Wickmann / Littelfuse

GDT 350V 10KA 3 POLE TH

0

GTCN38-900M-Q10

GTCN38-900M-Q10

Wickmann / Littelfuse

GDT 90V 10KA 3 POLE

0

PMT3(310)35004F

PMT3(310)35004F

Wickmann / Littelfuse

GDT 350V 20KA 3 POLE TH

0

Gas Discharge Tube Arresters (GDT)

1. Overview

Gas Discharge Tube Arresters (GDT) are voltage-dependent overvoltage protection devices that utilize ionization of gas to divert high-voltage transients to ground. They act as switches that remain non-conductive under normal operating conditions but rapidly transition to a low-impedance state when voltage exceeds a specific threshold. GDTs play a critical role in safeguarding electronic systems from lightning strikes, electrostatic discharge (ESD), and other transient voltage events in telecommunications, power distribution, and industrial automation systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Single-Electrode GDTCompact design with one gas chamber, suitable for low-energy transientsConsumer electronics, IoT devices
Multi-Electrode GDTStacked electrodes for higher energy absorption and multi-stage protectionTelecom infrastructure, 5G base stations
Inert Gas GDTUses argon/neon for stable performance in harsh environmentsIndustrial control systems, aerospace
Metal Vapor GDTMercury/xenon vapor for ultra-fast response timesHigh-speed data lines, medical imaging equipment

3. Structure and Components

Typical GDT construction includes:

  • Ceramic or glass cylindrical body with hermetic sealing
  • Tungsten/copper alloy electrodes with precision spacing
  • Inert gas (e.g., argon, neon) or metal vapor filling
  • External insulation coating (epoxy/silicone rubber)
  • Threaded/metallic base for grounding connection

4. Key Technical Specifications

ParameterTypical RangeImportance
DC Spark-over Voltage70V 5kVDetermines trigger threshold
Impulse Spark-over Voltage100V 10kVResponse under fast transients
Max Discharge Current10kA 100kAOverload handling capability
Response Time0.1 s 1 sCritical for ESD protection
Dielectric Strength1kV 20kV/mmPost-event insulation recovery

5. Application Fields

Major industry applications include:

  • Telecommunications: DSL modems, fiber optic transceivers, antenna protection
  • Industrial Automation: PLC systems, motor drives, sensor networks
  • Renewable Energy: Solar inverter DC inputs, wind turbine control cabinets
  • Railway Systems: Signaling equipment, traction converter protection
  • Case Study: 5G Base Station Implementation
    • Multi-electrode GDTs protect RF front-end modules from lightning surges
    • Combined with TVS diodes for multi-level protection architecture
    • Reduces maintenance costs by 40% in coastal deployments

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
LittelfuseSPA-GDT SeriesHybrid gas-silicon integration, 10kA rating
Bourns2021 SeriesSurface-mount design, 500V breakdown
EatonPulsar GDT100kA max current, UL94 certified
MurataMA48 SeriesNano-coated ceramic body, -55 C~125 C operation

7. Selection Guidelines

Key considerations for GDT selection:

  1. Match breakdown voltage to system operating voltage (min. 1.2x nominal)
  2. Verify discharge current rating exceeds maximum expected surge (IEC 61643-11 compliance)
  3. Consider environmental factors (temperature, humidity, vibration)
  4. Assess mounting requirements (through-hole vs surface-mount)
  5. Coordinate with downstream protection devices for coordinated clamping
  6. Check certification standards (UL, CSA, RoHS)

8. Industry Trends

Future development directions:

  • Miniaturization for high-density PCB applications (sub-5mm diameters)
  • Advanced nanogap technologies for sub-nanosecond response times
  • Integration with AI-based predictive maintenance systems
  • Development of eco-friendly alternative gases to replace SF6
  • Wide bandgap semiconductor hybrid protection devices
  • Increased adoption in EV charging infrastructure (DC fast chargers)

RFQ BOM Call Skype Email
Top