Gas Discharge Tube Arresters (GDT)

Image Part Number Description / PDF Quantity Rfq
GTCN28-231M-R10

GTCN28-231M-R10

Wickmann / Littelfuse

GDT 230V 10KA 2 POLE

0

CG110

CG110

Wickmann / Littelfuse

GDT 110V 20KA 2 POLE

0

SL1003A450C

SL1003A450C

Wickmann / Littelfuse

GDT 450V 10KA 3 POLE

0

CG5150MS

CG5150MS

Wickmann / Littelfuse

GDT 150V 5KA 2 POLE SMD

0

GTCA26-151M-R05-FS

GTCA26-151M-R05-FS

Wickmann / Littelfuse

GDT 150V 5KA 2 POLE THROUGH HOLE

0

SG300

SG300

Wickmann / Littelfuse

GDT 300V 1KA 2 POLE SMD

703

CG5145LTR

CG5145LTR

Wickmann / Littelfuse

GDT 145V 5KA 2 POLE THROUGH HOLE

0

SG300Q

SG300Q

Wickmann / Littelfuse

GDT 300V 1KA 2 POLE SMD

1799

CG5600L

CG5600L

Wickmann / Littelfuse

GDT 600V 5KA 2 POLE THROUGH HOLE

0

GTCA38-501M-R10

GTCA38-501M-R10

Wickmann / Littelfuse

GDT 500V 10KA 3 POLE TH

0

CG2470L

CG2470L

Wickmann / Littelfuse

GDT 470V 20KA 2 POLE TH

341

CG2350SN

CG2350SN

Wickmann / Littelfuse

GDT 350V 20KA 2 POLE

0

GTCN36-251M-R10

GTCN36-251M-R10

Wickmann / Littelfuse

GDT 250V 10KA 3 POLE

0

SL1003A350C

SL1003A350C

Wickmann / Littelfuse

GDT 350V 10KA 3 POLE

0

SL1021B250CF

SL1021B250CF

Wickmann / Littelfuse

GDT 250V 20KA 3 POLE

0

CG90

CG90

Wickmann / Littelfuse

GDT 90V 20KA 2 POLE

0

GTCS36-900M-R05-2

GTCS36-900M-R05-2

Wickmann / Littelfuse

GDT 90V 5KA 3 POLE SURFACE MOUNT

0

GTCA35-351M-R05

GTCA35-351M-R05

Wickmann / Littelfuse

GDT 350V 5KA 3 POLE THROUGH HOLE

0

GTCA38-401M-R10-FS2

GTCA38-401M-R10-FS2

Wickmann / Littelfuse

GDT 400V 10KA 3 POLE TH

0

GTCA25-750M-R02

GTCA25-750M-R02

Wickmann / Littelfuse

GDT 75V 2.5KA 2 POLE TH

972

Gas Discharge Tube Arresters (GDT)

1. Overview

Gas Discharge Tube Arresters (GDT) are voltage-dependent overvoltage protection devices that utilize ionization of gas to divert high-voltage transients to ground. They act as switches that remain non-conductive under normal operating conditions but rapidly transition to a low-impedance state when voltage exceeds a specific threshold. GDTs play a critical role in safeguarding electronic systems from lightning strikes, electrostatic discharge (ESD), and other transient voltage events in telecommunications, power distribution, and industrial automation systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Single-Electrode GDTCompact design with one gas chamber, suitable for low-energy transientsConsumer electronics, IoT devices
Multi-Electrode GDTStacked electrodes for higher energy absorption and multi-stage protectionTelecom infrastructure, 5G base stations
Inert Gas GDTUses argon/neon for stable performance in harsh environmentsIndustrial control systems, aerospace
Metal Vapor GDTMercury/xenon vapor for ultra-fast response timesHigh-speed data lines, medical imaging equipment

3. Structure and Components

Typical GDT construction includes:

  • Ceramic or glass cylindrical body with hermetic sealing
  • Tungsten/copper alloy electrodes with precision spacing
  • Inert gas (e.g., argon, neon) or metal vapor filling
  • External insulation coating (epoxy/silicone rubber)
  • Threaded/metallic base for grounding connection

4. Key Technical Specifications

ParameterTypical RangeImportance
DC Spark-over Voltage70V 5kVDetermines trigger threshold
Impulse Spark-over Voltage100V 10kVResponse under fast transients
Max Discharge Current10kA 100kAOverload handling capability
Response Time0.1 s 1 sCritical for ESD protection
Dielectric Strength1kV 20kV/mmPost-event insulation recovery

5. Application Fields

Major industry applications include:

  • Telecommunications: DSL modems, fiber optic transceivers, antenna protection
  • Industrial Automation: PLC systems, motor drives, sensor networks
  • Renewable Energy: Solar inverter DC inputs, wind turbine control cabinets
  • Railway Systems: Signaling equipment, traction converter protection
  • Case Study: 5G Base Station Implementation
    • Multi-electrode GDTs protect RF front-end modules from lightning surges
    • Combined with TVS diodes for multi-level protection architecture
    • Reduces maintenance costs by 40% in coastal deployments

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
LittelfuseSPA-GDT SeriesHybrid gas-silicon integration, 10kA rating
Bourns2021 SeriesSurface-mount design, 500V breakdown
EatonPulsar GDT100kA max current, UL94 certified
MurataMA48 SeriesNano-coated ceramic body, -55 C~125 C operation

7. Selection Guidelines

Key considerations for GDT selection:

  1. Match breakdown voltage to system operating voltage (min. 1.2x nominal)
  2. Verify discharge current rating exceeds maximum expected surge (IEC 61643-11 compliance)
  3. Consider environmental factors (temperature, humidity, vibration)
  4. Assess mounting requirements (through-hole vs surface-mount)
  5. Coordinate with downstream protection devices for coordinated clamping
  6. Check certification standards (UL, CSA, RoHS)

8. Industry Trends

Future development directions:

  • Miniaturization for high-density PCB applications (sub-5mm diameters)
  • Advanced nanogap technologies for sub-nanosecond response times
  • Integration with AI-based predictive maintenance systems
  • Development of eco-friendly alternative gases to replace SF6
  • Wide bandgap semiconductor hybrid protection devices
  • Increased adoption in EV charging infrastructure (DC fast chargers)

RFQ BOM Call Skype Email
Top