Gas Discharge Tube Arresters (GDT)

Image Part Number Description / PDF Quantity Rfq
B88069X5020T103

B88069X5020T103

TDK EPCOS

GDT 90V 5KA 2 POLE THROUGH HOLE

1558

B88069X4131S102

B88069X4131S102

TDK EPCOS

GDT 230V 5KA 2 POLE THROUGH HOLE

945

B88069X7540B202

B88069X7540B202

TDK EPCOS

GDT 230V 20KA 3 POLE TH

196

B88069X9680B252

B88069X9680B252

TDK EPCOS

GDT 230V 10KA 3 POLE TH

0

B88069X1630T602

B88069X1630T602

TDK EPCOS

GDT 90V 20KA 2 POLE SMD

670

B88069X6381T902

B88069X6381T902

TDK EPCOS

GDT 150V 2.5KA 2 POLE SMD

584

B88069X7990B502

B88069X7990B502

TDK EPCOS

GDT 300V 10KA 3 POLE TH

0

B88069X3500T502

B88069X3500T502

TDK EPCOS

GDT 1400V 10KA 2 POLE TH

940

B88069X0800S102

B88069X0800S102

TDK EPCOS

GDT 270V 2.5KA 2 POLE TH

0

B88069X7891T352

B88069X7891T352

TDK EPCOS

GAS DISCHARGE TUBE 90V

0

EZ3-A230XF1

EZ3-A230XF1

TDK EPCOS

GDT 230V 5KA 3 POLE THROUGH HOLE

0

B88069X3351T902

B88069X3351T902

TDK EPCOS

GDT 600V 5KA 2 POLE SMD

0

B88069X4640C102

B88069X4640C102

TDK EPCOS

GDT 350V 5KA 2 POLE THROUGH HOLE

1188

B88069X1923T902

B88069X1923T902

TDK EPCOS

GDT 230V 5KA 2 POLE SMD

1215

B88069X4960T502

B88069X4960T502

TDK EPCOS

GDT 230V 10KA 2 POLE TH

0

B88069X4653T173

B88069X4653T173

TDK EPCOS

GDT 90V 10KA 2 POLE SMD

1681

B88069X1490S102

B88069X1490S102

TDK EPCOS

GDT 500V 20KA 2 POLE TH

3824

B88069X2230C103

B88069X2230C103

TDK EPCOS

GDT 350V 20KA 2 POLE

993

B88069X2930C102

B88069X2930C102

TDK EPCOS

GDT 230V 5KA 2 POLE THROUGH HOLE

358

B88069X0780S102

B88069X0780S102

TDK EPCOS

GDT 540V 5KA 2 POLE THROUGH HOLE

7714

Gas Discharge Tube Arresters (GDT)

1. Overview

Gas Discharge Tube Arresters (GDT) are voltage-dependent overvoltage protection devices that utilize ionization of gas to divert high-voltage transients to ground. They act as switches that remain non-conductive under normal operating conditions but rapidly transition to a low-impedance state when voltage exceeds a specific threshold. GDTs play a critical role in safeguarding electronic systems from lightning strikes, electrostatic discharge (ESD), and other transient voltage events in telecommunications, power distribution, and industrial automation systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Single-Electrode GDTCompact design with one gas chamber, suitable for low-energy transientsConsumer electronics, IoT devices
Multi-Electrode GDTStacked electrodes for higher energy absorption and multi-stage protectionTelecom infrastructure, 5G base stations
Inert Gas GDTUses argon/neon for stable performance in harsh environmentsIndustrial control systems, aerospace
Metal Vapor GDTMercury/xenon vapor for ultra-fast response timesHigh-speed data lines, medical imaging equipment

3. Structure and Components

Typical GDT construction includes:

  • Ceramic or glass cylindrical body with hermetic sealing
  • Tungsten/copper alloy electrodes with precision spacing
  • Inert gas (e.g., argon, neon) or metal vapor filling
  • External insulation coating (epoxy/silicone rubber)
  • Threaded/metallic base for grounding connection

4. Key Technical Specifications

ParameterTypical RangeImportance
DC Spark-over Voltage70V 5kVDetermines trigger threshold
Impulse Spark-over Voltage100V 10kVResponse under fast transients
Max Discharge Current10kA 100kAOverload handling capability
Response Time0.1 s 1 sCritical for ESD protection
Dielectric Strength1kV 20kV/mmPost-event insulation recovery

5. Application Fields

Major industry applications include:

  • Telecommunications: DSL modems, fiber optic transceivers, antenna protection
  • Industrial Automation: PLC systems, motor drives, sensor networks
  • Renewable Energy: Solar inverter DC inputs, wind turbine control cabinets
  • Railway Systems: Signaling equipment, traction converter protection
  • Case Study: 5G Base Station Implementation
    • Multi-electrode GDTs protect RF front-end modules from lightning surges
    • Combined with TVS diodes for multi-level protection architecture
    • Reduces maintenance costs by 40% in coastal deployments

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
LittelfuseSPA-GDT SeriesHybrid gas-silicon integration, 10kA rating
Bourns2021 SeriesSurface-mount design, 500V breakdown
EatonPulsar GDT100kA max current, UL94 certified
MurataMA48 SeriesNano-coated ceramic body, -55 C~125 C operation

7. Selection Guidelines

Key considerations for GDT selection:

  1. Match breakdown voltage to system operating voltage (min. 1.2x nominal)
  2. Verify discharge current rating exceeds maximum expected surge (IEC 61643-11 compliance)
  3. Consider environmental factors (temperature, humidity, vibration)
  4. Assess mounting requirements (through-hole vs surface-mount)
  5. Coordinate with downstream protection devices for coordinated clamping
  6. Check certification standards (UL, CSA, RoHS)

8. Industry Trends

Future development directions:

  • Miniaturization for high-density PCB applications (sub-5mm diameters)
  • Advanced nanogap technologies for sub-nanosecond response times
  • Integration with AI-based predictive maintenance systems
  • Development of eco-friendly alternative gases to replace SF6
  • Wide bandgap semiconductor hybrid protection devices
  • Increased adoption in EV charging infrastructure (DC fast chargers)