Gas Discharge Tube Arresters (GDT)

Image Part Number Description / PDF Quantity Rfq
B88069X8710C203

B88069X8710C203

TDK EPCOS

GDT 230V 20KA 3 POLE

0

B88069X9260B502

B88069X9260B502

TDK EPCOS

GDT 230V 10KA 3 POLE TH

0

B88069X6660T103

B88069X6660T103

TDK EPCOS

GDT 176V 5KA 3 POLE SMD

0

B88069X2631C253

B88069X2631C253

TDK EPCOS

GDT 600V 5KA 2 POLE

0

B88069X7401B502

B88069X7401B502

TDK EPCOS

GAS DISCHARGE TUBE

0

B88069X7970B502

B88069X7970B502

TDK EPCOS

GAS DISCHARGE TUBE

0

B88069X9900B502

B88069X9900B502

TDK EPCOS

T23-A420XF4

0

B88069X4570T103

B88069X4570T103

TDK EPCOS

GDT 510V 10KA 2 POLE TH

0

B88069X0850T502

B88069X0850T502

TDK EPCOS

GDT 230V 5KA 2 POLE THROUGH HOLE

0

B88069X9370B502

B88069X9370B502

TDK EPCOS

GAS DISCHARGE TUBE

0

B88069X4580C253

B88069X4580C253

TDK EPCOS

GDT 260V 10KA 2 POLE

0

B88069X9311T203

B88069X9311T203

TDK EPCOS

GDT 420V 2KA 2 POLE SMD

0

B88069X5041S102

B88069X5041S102

TDK EPCOS

GDT 800V 10KA 2 POLE TH

0

B88069X2910S102

B88069X2910S102

TDK EPCOS

GDT 550V 2.5KA 2 POLE TH

0

B88069X1490T502

B88069X1490T502

TDK EPCOS

GDT 500V 20KA 2 POLE TH

0

B88069X4480T902

B88069X4480T902

TDK EPCOS

GDT 90V 10KA 2 POLE SMD

0

B88069X9020B502

B88069X9020B502

TDK EPCOS

GAS DISCHARGE TUBE

0

B88069X6710C253

B88069X6710C253

TDK EPCOS

GDT 176V 5KA 3 POLE

0

B88069X6700C253

B88069X6700C253

TDK EPCOS

GDT 176V 5KA 3 POLE

0

B88069X4700T103

B88069X4700T103

TDK EPCOS

GDT 230V 5KA 2 POLE THROUGH HOLE

0

Gas Discharge Tube Arresters (GDT)

1. Overview

Gas Discharge Tube Arresters (GDT) are voltage-dependent overvoltage protection devices that utilize ionization of gas to divert high-voltage transients to ground. They act as switches that remain non-conductive under normal operating conditions but rapidly transition to a low-impedance state when voltage exceeds a specific threshold. GDTs play a critical role in safeguarding electronic systems from lightning strikes, electrostatic discharge (ESD), and other transient voltage events in telecommunications, power distribution, and industrial automation systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Single-Electrode GDTCompact design with one gas chamber, suitable for low-energy transientsConsumer electronics, IoT devices
Multi-Electrode GDTStacked electrodes for higher energy absorption and multi-stage protectionTelecom infrastructure, 5G base stations
Inert Gas GDTUses argon/neon for stable performance in harsh environmentsIndustrial control systems, aerospace
Metal Vapor GDTMercury/xenon vapor for ultra-fast response timesHigh-speed data lines, medical imaging equipment

3. Structure and Components

Typical GDT construction includes:

  • Ceramic or glass cylindrical body with hermetic sealing
  • Tungsten/copper alloy electrodes with precision spacing
  • Inert gas (e.g., argon, neon) or metal vapor filling
  • External insulation coating (epoxy/silicone rubber)
  • Threaded/metallic base for grounding connection

4. Key Technical Specifications

ParameterTypical RangeImportance
DC Spark-over Voltage70V 5kVDetermines trigger threshold
Impulse Spark-over Voltage100V 10kVResponse under fast transients
Max Discharge Current10kA 100kAOverload handling capability
Response Time0.1 s 1 sCritical for ESD protection
Dielectric Strength1kV 20kV/mmPost-event insulation recovery

5. Application Fields

Major industry applications include:

  • Telecommunications: DSL modems, fiber optic transceivers, antenna protection
  • Industrial Automation: PLC systems, motor drives, sensor networks
  • Renewable Energy: Solar inverter DC inputs, wind turbine control cabinets
  • Railway Systems: Signaling equipment, traction converter protection
  • Case Study: 5G Base Station Implementation
    • Multi-electrode GDTs protect RF front-end modules from lightning surges
    • Combined with TVS diodes for multi-level protection architecture
    • Reduces maintenance costs by 40% in coastal deployments

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
LittelfuseSPA-GDT SeriesHybrid gas-silicon integration, 10kA rating
Bourns2021 SeriesSurface-mount design, 500V breakdown
EatonPulsar GDT100kA max current, UL94 certified
MurataMA48 SeriesNano-coated ceramic body, -55 C~125 C operation

7. Selection Guidelines

Key considerations for GDT selection:

  1. Match breakdown voltage to system operating voltage (min. 1.2x nominal)
  2. Verify discharge current rating exceeds maximum expected surge (IEC 61643-11 compliance)
  3. Consider environmental factors (temperature, humidity, vibration)
  4. Assess mounting requirements (through-hole vs surface-mount)
  5. Coordinate with downstream protection devices for coordinated clamping
  6. Check certification standards (UL, CSA, RoHS)

8. Industry Trends

Future development directions:

  • Miniaturization for high-density PCB applications (sub-5mm diameters)
  • Advanced nanogap technologies for sub-nanosecond response times
  • Integration with AI-based predictive maintenance systems
  • Development of eco-friendly alternative gases to replace SF6
  • Wide bandgap semiconductor hybrid protection devices
  • Increased adoption in EV charging infrastructure (DC fast chargers)

RFQ BOM Call Skype Email
Top