Gas Discharge Tube Arresters (GDT)

Image Part Number Description / PDF Quantity Rfq
B88069X2633B252

B88069X2633B252

TDK EPCOS

GDT 4000V 3KA 2 POLE TH

324

B88069X8750B502

B88069X8750B502

TDK EPCOS

GDT 230V 20KA 3 POLE TH

0

B88069X4051T902

B88069X4051T902

TDK EPCOS

GDT 90V 5KA 3 POLE SURFACE MOUNT

8673

B88069X4560T103

B88069X4560T103

TDK EPCOS

GDT 570V 5KA 2 POLE THROUGH HOLE

1135

B88069X8361T203

B88069X8361T203

TDK EPCOS

GDT 350V 2KA 2 POLE SMD

1450

B88069X4420B152

B88069X4420B152

TDK EPCOS

GDT 2200V 20KA 2 POLE CHASSIS

599

B88069X6071T203

B88069X6071T203

TDK EPCOS

GDT 150V 2KA 2 POLE SMD

0

B88069X2261B252

B88069X2261B252

TDK EPCOS

GDT 90V 10KA 3 POLE THROUGH HOLE

1244

B88069X1360C103

B88069X1360C103

TDK EPCOS

GDT 90V 20KA 2 POLE THROUGH HOLE

53

B88069X9590B502

B88069X9590B502

TDK EPCOS

GDT 150V 10KA 3 POLE TH

1000

B88069X4030T902

B88069X4030T902

TDK EPCOS

GDT 350V 5KA 3 POLE SMD

11

B88069X5941T203

B88069X5941T203

TDK EPCOS

GDT 230V 1KA 2 POLE SMD

650

B88069X2710B502

B88069X2710B502

TDK EPCOS

GDT 260V 10KA 3 POLE TH

471

B88069X7200B102

B88069X7200B102

TDK EPCOS

GDT 350V 20KA 3 POLE TH

455

B88069X2900C103

B88069X2900C103

TDK EPCOS

GDT 600V 20KA 2 POLE

627

B88069X2090S102

B88069X2090S102

TDK EPCOS

GDT 1200V 10KA 2 POLE TH

5291

B88069X5690T502

B88069X5690T502

TDK EPCOS

GDT 2500V 2.5KA 2 POLE TH

1000

B88069X4301S102

B88069X4301S102

TDK EPCOS

GDT 1500V 5KA 2 POLE TH

0

B88069X5591T902

B88069X5591T902

TDK EPCOS

GDT 400V 2.5KA 2 POLE SMD

2209

B88069X4830S102

B88069X4830S102

TDK EPCOS

GDT 350V 10KA 2 POLE TH

0

Gas Discharge Tube Arresters (GDT)

1. Overview

Gas Discharge Tube Arresters (GDT) are voltage-dependent overvoltage protection devices that utilize ionization of gas to divert high-voltage transients to ground. They act as switches that remain non-conductive under normal operating conditions but rapidly transition to a low-impedance state when voltage exceeds a specific threshold. GDTs play a critical role in safeguarding electronic systems from lightning strikes, electrostatic discharge (ESD), and other transient voltage events in telecommunications, power distribution, and industrial automation systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Single-Electrode GDTCompact design with one gas chamber, suitable for low-energy transientsConsumer electronics, IoT devices
Multi-Electrode GDTStacked electrodes for higher energy absorption and multi-stage protectionTelecom infrastructure, 5G base stations
Inert Gas GDTUses argon/neon for stable performance in harsh environmentsIndustrial control systems, aerospace
Metal Vapor GDTMercury/xenon vapor for ultra-fast response timesHigh-speed data lines, medical imaging equipment

3. Structure and Components

Typical GDT construction includes:

  • Ceramic or glass cylindrical body with hermetic sealing
  • Tungsten/copper alloy electrodes with precision spacing
  • Inert gas (e.g., argon, neon) or metal vapor filling
  • External insulation coating (epoxy/silicone rubber)
  • Threaded/metallic base for grounding connection

4. Key Technical Specifications

ParameterTypical RangeImportance
DC Spark-over Voltage70V 5kVDetermines trigger threshold
Impulse Spark-over Voltage100V 10kVResponse under fast transients
Max Discharge Current10kA 100kAOverload handling capability
Response Time0.1 s 1 sCritical for ESD protection
Dielectric Strength1kV 20kV/mmPost-event insulation recovery

5. Application Fields

Major industry applications include:

  • Telecommunications: DSL modems, fiber optic transceivers, antenna protection
  • Industrial Automation: PLC systems, motor drives, sensor networks
  • Renewable Energy: Solar inverter DC inputs, wind turbine control cabinets
  • Railway Systems: Signaling equipment, traction converter protection
  • Case Study: 5G Base Station Implementation
    • Multi-electrode GDTs protect RF front-end modules from lightning surges
    • Combined with TVS diodes for multi-level protection architecture
    • Reduces maintenance costs by 40% in coastal deployments

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
LittelfuseSPA-GDT SeriesHybrid gas-silicon integration, 10kA rating
Bourns2021 SeriesSurface-mount design, 500V breakdown
EatonPulsar GDT100kA max current, UL94 certified
MurataMA48 SeriesNano-coated ceramic body, -55 C~125 C operation

7. Selection Guidelines

Key considerations for GDT selection:

  1. Match breakdown voltage to system operating voltage (min. 1.2x nominal)
  2. Verify discharge current rating exceeds maximum expected surge (IEC 61643-11 compliance)
  3. Consider environmental factors (temperature, humidity, vibration)
  4. Assess mounting requirements (through-hole vs surface-mount)
  5. Coordinate with downstream protection devices for coordinated clamping
  6. Check certification standards (UL, CSA, RoHS)

8. Industry Trends

Future development directions:

  • Miniaturization for high-density PCB applications (sub-5mm diameters)
  • Advanced nanogap technologies for sub-nanosecond response times
  • Integration with AI-based predictive maintenance systems
  • Development of eco-friendly alternative gases to replace SF6
  • Wide bandgap semiconductor hybrid protection devices
  • Increased adoption in EV charging infrastructure (DC fast chargers)