Gas Discharge Tube Arresters (GDT)

Image Part Number Description / PDF Quantity Rfq
2018-23-SMH-RPLF

2018-23-SMH-RPLF

J.W. Miller / Bourns

GDT 230V 20KA 3 POLE SMD HORIZ

1580

2003-23-SM-RPLF

2003-23-SM-RPLF

J.W. Miller / Bourns

GDT 230V 1KA 2 POLE SMD

2410

DE37-272M-S00B

DE37-272M-S00B

Mitsubishi Materials U.S.A

GDT 2700V 1.5KA 2 POLE TH

200

GTCA26-251M-R05-2

GTCA26-251M-R05-2

Wickmann / Littelfuse

GDT 250V 5KA 2 POLE THROUGH HOLE

0

2036-60-SMLF

2036-60-SMLF

J.W. Miller / Bourns

GDT 600V 10KA 3 POLE SMD

0

2027-09-CLF

2027-09-CLF

J.W. Miller / Bourns

GDT 90V 10KA 2 POLE THROUGH HOLE

1140

2035-60-SMLF

2035-60-SMLF

J.W. Miller / Bourns

GDT 600V 5KA 2 POLE SMD

0

2026-23-C3LF

2026-23-C3LF

J.W. Miller / Bourns

GDT 230V 20KA 3 POLE TH

0

B88069X6461S102

B88069X6461S102

TDK EPCOS

GDT 600V 5KA 2 POLE THROUGH HOLE

41

2033-140-G5-T1LF

2033-140-G5-T1LF

J.W. Miller / Bourns

GDT 1400V 20KA 2 POLE

0

2095-500-CT1LF

2095-500-CT1LF

J.W. Miller / Bourns

GDT 5000V 5KA 2 POLE TH

0

2046-25-C2LF

2046-25-C2LF

J.W. Miller / Bourns

GDT 250V 10KA 3 POLE TH

0

2026-15-C4LF

2026-15-C4LF

J.W. Miller / Bourns

GDT 150V 20KA 3 POLE TH

0

2049-23-BT1LF

2049-23-BT1LF

J.W. Miller / Bourns

GDT 230V 15KA 2 POLE TH

0

2035-40-SM-RP

2035-40-SM-RP

J.W. Miller / Bourns

GDT 400V 5KA 2 POLE SMD

0

SA2-2400-CLB-STD

SA2-2400-CLB-STD

J.W. Miller / Bourns

GDT 2400V 5KA 2 POLE TH

0

SA2-3000-CLT-STD

SA2-3000-CLT-STD

J.W. Miller / Bourns

GDT 3000V 5KA 2 POLE TH

0

CG33.3

CG33.3

Wickmann / Littelfuse

GDT 3300V 5KA 2 POLE

0

CG31.2

CG31.2

Wickmann / Littelfuse

GDT 1200V 5KA 2 POLE

0

GTCR36-231M-R10

GTCR36-231M-R10

Wickmann / Littelfuse

GDT 230V 10KA 3 POLE TH

284

Gas Discharge Tube Arresters (GDT)

1. Overview

Gas Discharge Tube Arresters (GDT) are voltage-dependent overvoltage protection devices that utilize ionization of gas to divert high-voltage transients to ground. They act as switches that remain non-conductive under normal operating conditions but rapidly transition to a low-impedance state when voltage exceeds a specific threshold. GDTs play a critical role in safeguarding electronic systems from lightning strikes, electrostatic discharge (ESD), and other transient voltage events in telecommunications, power distribution, and industrial automation systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Single-Electrode GDTCompact design with one gas chamber, suitable for low-energy transientsConsumer electronics, IoT devices
Multi-Electrode GDTStacked electrodes for higher energy absorption and multi-stage protectionTelecom infrastructure, 5G base stations
Inert Gas GDTUses argon/neon for stable performance in harsh environmentsIndustrial control systems, aerospace
Metal Vapor GDTMercury/xenon vapor for ultra-fast response timesHigh-speed data lines, medical imaging equipment

3. Structure and Components

Typical GDT construction includes:

  • Ceramic or glass cylindrical body with hermetic sealing
  • Tungsten/copper alloy electrodes with precision spacing
  • Inert gas (e.g., argon, neon) or metal vapor filling
  • External insulation coating (epoxy/silicone rubber)
  • Threaded/metallic base for grounding connection

4. Key Technical Specifications

ParameterTypical RangeImportance
DC Spark-over Voltage70V 5kVDetermines trigger threshold
Impulse Spark-over Voltage100V 10kVResponse under fast transients
Max Discharge Current10kA 100kAOverload handling capability
Response Time0.1 s 1 sCritical for ESD protection
Dielectric Strength1kV 20kV/mmPost-event insulation recovery

5. Application Fields

Major industry applications include:

  • Telecommunications: DSL modems, fiber optic transceivers, antenna protection
  • Industrial Automation: PLC systems, motor drives, sensor networks
  • Renewable Energy: Solar inverter DC inputs, wind turbine control cabinets
  • Railway Systems: Signaling equipment, traction converter protection
  • Case Study: 5G Base Station Implementation
    • Multi-electrode GDTs protect RF front-end modules from lightning surges
    • Combined with TVS diodes for multi-level protection architecture
    • Reduces maintenance costs by 40% in coastal deployments

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
LittelfuseSPA-GDT SeriesHybrid gas-silicon integration, 10kA rating
Bourns2021 SeriesSurface-mount design, 500V breakdown
EatonPulsar GDT100kA max current, UL94 certified
MurataMA48 SeriesNano-coated ceramic body, -55 C~125 C operation

7. Selection Guidelines

Key considerations for GDT selection:

  1. Match breakdown voltage to system operating voltage (min. 1.2x nominal)
  2. Verify discharge current rating exceeds maximum expected surge (IEC 61643-11 compliance)
  3. Consider environmental factors (temperature, humidity, vibration)
  4. Assess mounting requirements (through-hole vs surface-mount)
  5. Coordinate with downstream protection devices for coordinated clamping
  6. Check certification standards (UL, CSA, RoHS)

8. Industry Trends

Future development directions:

  • Miniaturization for high-density PCB applications (sub-5mm diameters)
  • Advanced nanogap technologies for sub-nanosecond response times
  • Integration with AI-based predictive maintenance systems
  • Development of eco-friendly alternative gases to replace SF6
  • Wide bandgap semiconductor hybrid protection devices
  • Increased adoption in EV charging infrastructure (DC fast chargers)