Gas Discharge Tube Arresters (GDT)

Image Part Number Description / PDF Quantity Rfq
B88069X8650B502

B88069X8650B502

TDK EPCOS

GDT 90V 20KA 3 POLE THROUGH HOLE

0

SL1010A170SMF

SL1010A170SMF

Wickmann / Littelfuse

GDT 170V 5KA 3 POLE SMD

0

B88069X5860T902

B88069X5860T902

TDK EPCOS

GAS DISCHARGE TUBE 90V

0

GTCR38-421L-R10

GTCR38-421L-R10

Wickmann / Littelfuse

GDT 420V 10KA 3 POLE TH

0

CG31.5L

CG31.5L

Wickmann / Littelfuse

GDT 1500V 5KA 2 POLE TH

1648

NTE15045-ECG

NTE15045-ECG

NTE Electronics, Inc.

GDT 300V 20KA 2 POLE TH

135

B88069X3513B252

B88069X3513B252

TDK EPCOS

GDT 3000V 3KA 2 POLE TH

501

B88069X2643B252

B88069X2643B252

TDK EPCOS

GDT 4500V 3KA 2 POLE TH

293

GTCS25-351M-R05

GTCS25-351M-R05

Wickmann / Littelfuse

GDT 350V 5KA 2 POLE SMD

0

SE140

SE140

Wickmann / Littelfuse

GDT 140V 500A 2 POLE SMD

5987

SL1021B500R

SL1021B500R

Wickmann / Littelfuse

GDT 500V 20KA 3 POLE TH

0

CG5600LTR

CG5600LTR

Wickmann / Littelfuse

GDT 600V 5KA 2 POLE THROUGH HOLE

0

2027-23-B10

2027-23-B10

J.W. Miller / Bourns

GDT 230V 10KA 2 POLE TH

0

2051-09-SM-RPLF

2051-09-SM-RPLF

J.W. Miller / Bourns

GDT 90V 2KA 2 POLE SURFACE MOUNT

59580

SL1021A450RF

SL1021A450RF

Wickmann / Littelfuse

GDT 450V 10KA 3 POLE TH

0

GTCS35-401M-R05-2

GTCS35-401M-R05-2

Wickmann / Littelfuse

GDT 400V 5KA 3 POLE SMD

0

2026-33-C2F

2026-33-C2F

J.W. Miller / Bourns

GDT 330V 20KA 3 POLE TH

0

CG2300LTR

CG2300LTR

Wickmann / Littelfuse

GDT 300V 20KA 2 POLE TH

0

2036-23-AF

2036-23-AF

J.W. Miller / Bourns

GDT 230V 10KA 3 POLE

0

B88069X4300B152

B88069X4300B152

TDK EPCOS

GDT 1400V 20KA 2 POLE CHASSIS

44

Gas Discharge Tube Arresters (GDT)

1. Overview

Gas Discharge Tube Arresters (GDT) are voltage-dependent overvoltage protection devices that utilize ionization of gas to divert high-voltage transients to ground. They act as switches that remain non-conductive under normal operating conditions but rapidly transition to a low-impedance state when voltage exceeds a specific threshold. GDTs play a critical role in safeguarding electronic systems from lightning strikes, electrostatic discharge (ESD), and other transient voltage events in telecommunications, power distribution, and industrial automation systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Single-Electrode GDTCompact design with one gas chamber, suitable for low-energy transientsConsumer electronics, IoT devices
Multi-Electrode GDTStacked electrodes for higher energy absorption and multi-stage protectionTelecom infrastructure, 5G base stations
Inert Gas GDTUses argon/neon for stable performance in harsh environmentsIndustrial control systems, aerospace
Metal Vapor GDTMercury/xenon vapor for ultra-fast response timesHigh-speed data lines, medical imaging equipment

3. Structure and Components

Typical GDT construction includes:

  • Ceramic or glass cylindrical body with hermetic sealing
  • Tungsten/copper alloy electrodes with precision spacing
  • Inert gas (e.g., argon, neon) or metal vapor filling
  • External insulation coating (epoxy/silicone rubber)
  • Threaded/metallic base for grounding connection

4. Key Technical Specifications

ParameterTypical RangeImportance
DC Spark-over Voltage70V 5kVDetermines trigger threshold
Impulse Spark-over Voltage100V 10kVResponse under fast transients
Max Discharge Current10kA 100kAOverload handling capability
Response Time0.1 s 1 sCritical for ESD protection
Dielectric Strength1kV 20kV/mmPost-event insulation recovery

5. Application Fields

Major industry applications include:

  • Telecommunications: DSL modems, fiber optic transceivers, antenna protection
  • Industrial Automation: PLC systems, motor drives, sensor networks
  • Renewable Energy: Solar inverter DC inputs, wind turbine control cabinets
  • Railway Systems: Signaling equipment, traction converter protection
  • Case Study: 5G Base Station Implementation
    • Multi-electrode GDTs protect RF front-end modules from lightning surges
    • Combined with TVS diodes for multi-level protection architecture
    • Reduces maintenance costs by 40% in coastal deployments

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
LittelfuseSPA-GDT SeriesHybrid gas-silicon integration, 10kA rating
Bourns2021 SeriesSurface-mount design, 500V breakdown
EatonPulsar GDT100kA max current, UL94 certified
MurataMA48 SeriesNano-coated ceramic body, -55 C~125 C operation

7. Selection Guidelines

Key considerations for GDT selection:

  1. Match breakdown voltage to system operating voltage (min. 1.2x nominal)
  2. Verify discharge current rating exceeds maximum expected surge (IEC 61643-11 compliance)
  3. Consider environmental factors (temperature, humidity, vibration)
  4. Assess mounting requirements (through-hole vs surface-mount)
  5. Coordinate with downstream protection devices for coordinated clamping
  6. Check certification standards (UL, CSA, RoHS)

8. Industry Trends

Future development directions:

  • Miniaturization for high-density PCB applications (sub-5mm diameters)
  • Advanced nanogap technologies for sub-nanosecond response times
  • Integration with AI-based predictive maintenance systems
  • Development of eco-friendly alternative gases to replace SF6
  • Wide bandgap semiconductor hybrid protection devices
  • Increased adoption in EV charging infrastructure (DC fast chargers)

RFQ BOM Call Skype Email