Fuses

Image Part Number Description / PDF Quantity Rfq
ERB-RE5R00V

ERB-RE5R00V

Panasonic

FUSE BOARD MOUNT 5A 32VDC 0603

0

ERB-SD0R50U

ERB-SD0R50U

Panasonic

FUSE BOARD MNT 500MA 24VDC 0402

16236

ERB-RE0R50V

ERB-RE0R50V

Panasonic

FUSE BOARD MNT 500MA 32VDC 0603

8509

ERB-RG1R00V

ERB-RG1R00V

Panasonic

FUSE BOARD MOUNT 1A 63VDC 1206

0

ERB-RE1R40V

ERB-RE1R40V

Panasonic

FUSE BOARD MOUNT 1.4A 32VDC 0603

4680

ERB-RG2R50V

ERB-RG2R50V

Panasonic

FUSE BOARD MOUNT 2.5A 32VDC 1206

4705

ERB-SD1R25U

ERB-SD1R25U

Panasonic

FUSE BOARD MNT 1.25A 24VDC 0402

1254

ERB-SD1R00U

ERB-SD1R00U

Panasonic

FUSE BOARD MOUNT 1A 24VDC 0402

3409

ERB-RG1R50V

ERB-RG1R50V

Panasonic

FUSE BOARD MOUNT 1.5A 63VDC 1206

3985

ERB-RD1R00X

ERB-RD1R00X

Panasonic

FUSE BOARD MOUNT 1A 32VDC 0402

3343

ERB-RG0R50V

ERB-RG0R50V

Panasonic

FUSE BOARD MNT 500MA 63VDC 1206

3239

ERB-RD0R50X

ERB-RD0R50X

Panasonic

FUSE BOARD MNT 500MA 32VDC 0402

13403

ERB-RG4R00V

ERB-RG4R00V

Panasonic

FUSE BOARD MOUNT 4A 32VDC 1206

3774

ERB-RD0R75X

ERB-RD0R75X

Panasonic

FUSE BOARD MNT 750MA 32VDC 0402

6880

ERB-RD2R50X

ERB-RD2R50X

Panasonic

FUSE BOARD MOUNT 2.5A 32VDC 0402

8603

ERB-SE1R50U

ERB-SE1R50U

Panasonic

FUSE BOARD MOUNT 1.5A 32VDC 0603

74

ERB-RE1R50V

ERB-RE1R50V

Panasonic

FUSE BOARD MOUNT 1.5A 32VDC 0603

5000

UNHZ20200L

UNHZ20200L

Panasonic

FUSE BOARD MNT 1A 50VAC/VDC 2SMD

2523

ERB-SD1R50U

ERB-SD1R50U

Panasonic

FUSE BOARD MOUNT 1.5A 24VDC 0402

648

ERB-RE0R75V

ERB-RE0R75V

Panasonic

FUSE BOARD MNT 750MA 32VDC 0603

836

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email