Fuses

Image Part Number Description / PDF Quantity Rfq
TSA-125MA

TSA-125MA

OptiFuse

GLASS FUSE-6.3X32MM, SLOW 125MA

2351

SCA-10A

SCA-10A

OptiFuse

CERAMIC-6.3X32MM, SUPER FAST 10A

595

TSA-P-800MA

TSA-P-800MA

OptiFuse

GLASS FUSE-6.3X32MM, SLOW 800MA

950

FSC-P-10A

FSC-P-10A

OptiFuse

GLASS FUSE-5X20MM (UL), FAST 10A

1640

FSH-5A

FSH-5A

OptiFuse

AUTO GLASS - 1/4"X5/8", FAST 5A

40636

FSW-1A

FSW-1A

OptiFuse

AUTO GLASS - 1/4"X7/8", FAST 1A

2600

TPK-R-250MA

TPK-R-250MA

OptiFuse

CLASS M FUSE, TIME DELAY 250MA

30

FCD-6.3A

FCD-6.3A

OptiFuse

CERAMIC-5X20MM (IEC), FAST 6.3A

4990

APR58-UL-10A

APR58-UL-10A

OptiFuse

FUSE AUTO 10A 58VDC BLADE

1735

MIDA-60A

MIDA-60A

OptiFuse

LIMITER FUSE, FAST-ACTING, 60A

0

TCD-6.3A

TCD-6.3A

OptiFuse

CERAMIC-5X20MM (IEC), SLOW 6.3A

6274

TSE-P-1.5A

TSE-P-1.5A

OptiFuse

GLASS FUSE - 5X15MM, SLOW 1.5A

3376

TMR-200MA

TMR-200MA

OptiFuse

THRU HOLE FUSE, TIME DELAY 200MA

880

ANM-W-15A-18R

ANM-W-15A-18R

OptiFuse

FUSE AUTO 15A 32VDC BLADE MINI

1010

MGGA-125A

MGGA-125A

OptiFuse

LIMITER FUSE, TIME DELAY, 125A

477

TSC-800MA

TSC-800MA

OptiFuse

GLASS - 5X20MM (UL), SLOW 800MA

3039

FCD-800MA

FCD-800MA

OptiFuse

CERAMIC-5X20MM (IEC), FAST 800MA

3800

TCA-1.6A

TCA-1.6A

OptiFuse

CERAMIC FUSE-6.3X32MM, SLOW 1.6A

3963

APX-20A

APX-20A

OptiFuse

FUSE AUTO 20A 32VDC BLADE MAX

1079

FPK-5A

FPK-5A

OptiFuse

UL CLASS M FUSE, FAST ACTING 5A

44

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email