Fuses

Image Part Number Description / PDF Quantity Rfq
74-5SC3.15A

74-5SC3.15A

NTE Electronics, Inc.

FUSE CERAMIC 3.15A 250VAC 5X20MM

4030

74-5FG6.3A

74-5FG6.3A

NTE Electronics, Inc.

FUSE GLASS 6.3A 250VAC 5X20MM

1968

74-6SC1A

74-6SC1A

NTE Electronics, Inc.

FUSE CERAMIC 1A 250VAC 6X30MM

305

74-LAF5A

74-LAF5A

NTE Electronics, Inc.

FUSE AUTO 5A 32VDC BLADE

332

74-4FG2A

74-4FG2A

NTE Electronics, Inc.

FUSE GLASS 2A 250VAC 2AG

664

74-5SG500MA

74-5SG500MA

NTE Electronics, Inc.

FUSE GLASS 500MA 250VAC 5X20MM

396

74-4SGL800MA

74-4SGL800MA

NTE Electronics, Inc.

FUSE GLASS 800MA 250VAC 2AG

624

74-6SC250MA

74-6SC250MA

NTE Electronics, Inc.

FUSE CERAMIC 250MA 250VAC 6X30MM

657

74-5FC12A

74-5FC12A

NTE Electronics, Inc.

FUSE CERAMIC 12A 250VAC 5X20MM

502

74-XAF20A

74-XAF20A

NTE Electronics, Inc.

FUSE AUTO 20A 42VDC BLADE

608

74-5FG125MA

74-5FG125MA

NTE Electronics, Inc.

FUSE GLASS 125MA 250VAC 5X20MM

908

74-6SG125MA

74-6SG125MA

NTE Electronics, Inc.

FUSE GLASS 125MA 250VAC 6X30MM

494

74-5SCL12.5A

74-5SCL12.5A

NTE Electronics, Inc.

FUSE CERAMIC 12.5A 250VAC 5X20MM

372

74-5FG1.6A

74-5FG1.6A

NTE Electronics, Inc.

FUSE GLASS 1.6A 250VAC 5X20MM

3293

74-5SG750MA

74-5SG750MA

NTE Electronics, Inc.

FUSE GLASS 750MA 250VAC 5X20MM

3707

74-5FG10A

74-5FG10A

NTE Electronics, Inc.

FUSE GLASS 10A 250VAC 5X20MM

7173

74-5SC5A

74-5SC5A

NTE Electronics, Inc.

FUSE CERAMIC 5A 250VAC 5X20MM

2274

74-5SCL12A

74-5SCL12A

NTE Electronics, Inc.

FUSE CERAMIC 12A 250VAC 5X20MM

408

74-5SCL3.15A

74-5SCL3.15A

NTE Electronics, Inc.

FUSE CERAMIC 3.15A 250VAC 5X20MM

480

74-4SG3.5A

74-4SG3.5A

NTE Electronics, Inc.

FUSE GLASS 3.5A 250VAC 2AG

1549

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top