Fuses

Image Part Number Description / PDF Quantity Rfq
74-4FG750MA

74-4FG750MA

NTE Electronics, Inc.

FUSE GLASS 750MA 250VAC 2AG

1183

74-10FC4A

74-10FC4A

NTE Electronics, Inc.

FUSE CERAMIC 4A 1KVAC 1KVDC 5AG

15

74-AF3A

74-AF3A

NTE Electronics, Inc.

FUSE AUTO 3A 32VDC BLADE

1334

74-4FGL1A

74-4FGL1A

NTE Electronics, Inc.

FUSE GLASS 1A 250VAC 2AG

52

74-LPM-15A

74-LPM-15A

NTE Electronics, Inc.

AUTO FUSE 15A LOW PROFILE

388

74-5SCL500MA

74-5SCL500MA

NTE Electronics, Inc.

FUSE CERAMIC 500MA 250VAC 5X20MM

80

74-5FCL1A

74-5FCL1A

NTE Electronics, Inc.

FUSE CERAMIC 1A 250VAC 5X20MM

718

74-4FG1.5A

74-4FG1.5A

NTE Electronics, Inc.

FUSE GLASS 1.5A 125VAC 2AG

1772

74-5FC15A

74-5FC15A

NTE Electronics, Inc.

FUSE CERAMIC 15A 250VAC 5X20MM

180

74-5SG8A

74-5SG8A

NTE Electronics, Inc.

FUSE GLASS 8A 250VAC 5X20MM

0

74-4SG600MA

74-4SG600MA

NTE Electronics, Inc.

FUSE GLASS 600MA 250VAC 2AG

801

74-6FC2A

74-6FC2A

NTE Electronics, Inc.

FUSE CERAMIC 2A 250VAC 6X30MM

732

74-MS375MA

74-MS375MA

NTE Electronics, Inc.

FUSE BOARD MT 375MA 125VAC AXIAL

2750

74-4SG2A

74-4SG2A

NTE Electronics, Inc.

FUSE GLASS 2A 250VAC 2AG

1584

74-MS1A

74-MS1A

NTE Electronics, Inc.

FUSE BOARD MOUNT 1A 125VAC AXIAL

1093

74-6SG300MA

74-6SG300MA

NTE Electronics, Inc.

FUSE GLASS 300MA 250VAC 6X30MM

681

74-5FG400MA

74-5FG400MA

NTE Electronics, Inc.

FUSE GLASS 400MA 250VAC 5X20MM

1200

74-3SG2A

74-3SG2A

NTE Electronics, Inc.

FUSE GLASS 2A 250VAC CARTRIDGE

672

74-5FC2.5A

74-5FC2.5A

NTE Electronics, Inc.

FUSE CERAMIC 2.5A 250VAC 5X20MM

2425

74-5SG6A

74-5SG6A

NTE Electronics, Inc.

FUSE GLASS 6A 250VAC 5X20MM

334

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top