Fuses

Image Part Number Description / PDF Quantity Rfq
0239.700HXEP

0239.700HXEP

Wickmann / Littelfuse

FUSE GLASS 700MA 250VAC 5X20MM

0

0253.250V

0253.250V

Wickmann / Littelfuse

FUSE BOARD MNT 250MA 125VAC/VDC

0

044102.5WRA

044102.5WRA

Wickmann / Littelfuse

FUSE 2.5A 32V SMD 0603

1713

0315.125MXP

0315.125MXP

Wickmann / Littelfuse

FUSE GLASS 125MA 250VAC 3AB 3AG

0

0233010.MXEP

0233010.MXEP

Wickmann / Littelfuse

FUSE GLASS 10A 125VAC 5X20MM

0

0311005.M

0311005.M

Wickmann / Littelfuse

FUSE GLASS 5A 32VAC/VDC 3AB 3AG

1143

047202.5MRT1L

047202.5MRT1L

Wickmann / Littelfuse

FUSE BOARD MOUNT 2.5A 125VAC/VDC

0

0314012.HXP

0314012.HXP

Wickmann / Littelfuse

FUSE CERM 12A 250VAC 125VDC 3AB

3791000

0876.160MRET1P

0876.160MRET1P

Wickmann / Littelfuse

FUSE CERAMIC 160MA 250VAC AXIAL

0

0229.375VXP

0229.375VXP

Wickmann / Littelfuse

FUSE GLASS 375MA 250VAC 125VDC

0

37413150430

37413150430

Wickmann / Littelfuse

FUSE BRD MNT 3.15A 250VAC RADIAL

5

0407008.WR

0407008.WR

Wickmann / Littelfuse

FUSE 1206 63V T-LAG 8A

29909000

0451.400MRL

0451.400MRL

Wickmann / Littelfuse

FUSE BOARD MNT 400MA 125VAC/VDC

883

0453.160MR

0453.160MR

Wickmann / Littelfuse

FUSE BOARD MNT 160MA 125VAC/VDC

0

03261.25VXP

03261.25VXP

Wickmann / Littelfuse

FUSE CERAMIC 1.25A 250VAC 125VDC

0

LMIN07.5V

LMIN07.5V

Wickmann / Littelfuse

FUSE AUTO 7.5A 32VAC/VDC BLADE

0

0452001.NRL

0452001.NRL

Wickmann / Littelfuse

FUSE BRD MNT 1A 125VAC/VDC 2SMD

8558

ITV5432L1 230

ITV5432L1 230

Wickmann / Littelfuse

PTC RESETTABLE FUSE 12V 30A

30306000

0451.200MRL

0451.200MRL

Wickmann / Littelfuse

FUSE BOARD MNT 200MA 125VAC/VDC

4307

046801.5NR

046801.5NR

Wickmann / Littelfuse

FUSE BRD MNT 1.5A 63VAC/VDC 1206

709

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top