Fuses

Image Part Number Description / PDF Quantity Rfq
0325001.MXP

0325001.MXP

Wickmann / Littelfuse

FUSE CERM 1A 250VAC 125VDC 3AB

0

0219.125MXAEP

0219.125MXAEP

Wickmann / Littelfuse

FUSE GLASS 125MA 250VAC 5X20MM

0

0251003.MXL

0251003.MXL

Wickmann / Littelfuse

FUSE BRD MNT 3A 125VAC/VDC AXIAL

9939

ITV9550L4045

ITV9550L4045

Wickmann / Littelfuse

PTC RESETTABLE FUSE 40V 45A

10202000

20111250001

20111250001

Wickmann / Littelfuse

FUSE GLASS 1.25A 250VAC 5X20MM

0

38312000410

38312000410

Wickmann / Littelfuse

FUSE BOARD MOUNT 2A 300VAC RAD

0

023501.6MXEP

023501.6MXEP

Wickmann / Littelfuse

FUSE GLASS 1.6A 250VAC AXIAL

0

0326.031HXP

0326.031HXP

Wickmann / Littelfuse

FUSE CERAMIC 31MA 250VAC 3AB 3AG

0

0313.750VXP

0313.750VXP

Wickmann / Littelfuse

FUSE GLASS 750MA 250VAC 3AB 3AG

0

0326.062HXP

0326.062HXP

Wickmann / Littelfuse

FUSE CERAMIC 62MA 250VAC 3AB 3AG

0

40011000440

40011000440

Wickmann / Littelfuse

FUSE BOARD MNT 1A 250VAC RADIAL

0

0230003.DRT3P

0230003.DRT3P

Wickmann / Littelfuse

FUSE GLASS 3A 250VAC/125VDC AXL

0

0459005.ER

0459005.ER

Wickmann / Littelfuse

FUSE BRD MNT 5A 125VAC/VDC 2SMD

0

0232001.MXF15P

0232001.MXF15P

Wickmann / Littelfuse

FUSE GLASS 1A 250VAC 5X20MM

0

35612500029

35612500029

Wickmann / Littelfuse

FUSE CERAMIC 2.5A 440VAC 3AB 3AG

0

0287010.PXS

0287010.PXS

Wickmann / Littelfuse

FUSE ATO 32V NYLON SILVER 10A

306926000

021806.3MXEP

021806.3MXEP

Wickmann / Littelfuse

FUSE GLASS 6.3A 250VAC 5X20MM

2227

0448.315MR

0448.315MR

Wickmann / Littelfuse

FUSE BOARD MNT 315MA 125VAC/VDC

1829

0MAX030.X

0MAX030.X

Wickmann / Littelfuse

FUSE AUTO 30A 32VAC/VDC BLADE

0

0874.125MRET1P

0874.125MRET1P

Wickmann / Littelfuse

FUSE CERAMIC 125MA 250VAC AXIAL

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top