Fuses

Image Part Number Description / PDF Quantity Rfq
0235.700VXEP

0235.700VXEP

Wickmann / Littelfuse

FUSE GLASS 700MA 250VAC 5X20MM

0

0312.600HXP

0312.600HXP

Wickmann / Littelfuse

FUSE GLASS 600MA 250VAC 3AB 3AG

192

0251010.VXL

0251010.VXL

Wickmann / Littelfuse

FUSE BOARD MOUNT 10A 125VAC/VDC

0

023902.5MXEP

023902.5MXEP

Wickmann / Littelfuse

FUSE GLASS 2.5A 250VAC 5X20MM

0

1206SFP500F/32-2

1206SFP500F/32-2

Wickmann / Littelfuse

FUSE BOARD MOUNT 5A 32VDC 1206

2640

0278.400V

0278.400V

Wickmann / Littelfuse

FUSE BOARD MNT 400MA 125VAC/VDC

10

0224001.MXP

0224001.MXP

Wickmann / Littelfuse

FUSE GLASS 1A 250VAC 125VDC 2AG

1446

023406.3MXEP

023406.3MXEP

Wickmann / Littelfuse

FUSE CERAMIC 6.3A 250VAC 5X20MM

0

20101250001

20101250001

Wickmann / Littelfuse

FUSE GLASS 125MA 250VAC 5X20MM

0

0435004.KR

0435004.KR

Wickmann / Littelfuse

FUSE BOARD MOUNT 4A 32VDC 0402

0

0876005.MXEP

0876005.MXEP

Wickmann / Littelfuse

FUSE CERAMIC 5A 250VAC AXIAL

1024

0233003.MXP

0233003.MXP

Wickmann / Littelfuse

FUSE GLASS 3A 125VAC 5X20MM

0

0154002.DRL

0154002.DRL

Wickmann / Littelfuse

FUSE BOARD MNT 2A 125VAC/VDC SMD

1586

0217004.HXP

0217004.HXP

Wickmann / Littelfuse

FUSE GLASS 4A 250VAC 5X20MM

2915

046802.5WR

046802.5WR

Wickmann / Littelfuse

FUSE BRD MNT 2.5A 63VAC/VDC 1206

0

0235.125MXP

0235.125MXP

Wickmann / Littelfuse

FUSE GLASS 125MA 250VAC 5X20MM

1099

0230002.DRT2SP

0230002.DRT2SP

Wickmann / Littelfuse

FUSE GLASS 2A 250VAC/125VDC AXL

0

37000630000

37000630000

Wickmann / Littelfuse

FUSE BOARD MOUNT 63MA 250VAC RAD

0

0230.750DRT3P

0230.750DRT3P

Wickmann / Littelfuse

FUSE GLASS 750MA 250VAC 125VDC

0

02853.15HXP

02853.15HXP

Wickmann / Littelfuse

FUSE CERAMIC 3.15A 250VAC 5X20MM

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top