Fuses

Image Part Number Description / PDF Quantity Rfq
AGU-8

AGU-8

Eaton

BUSS MIDGET FUSE FAST ACTING

0

FLN-30

FLN-30

Eaton

FUSE AUTO 30A AUTO LINK

0

BP/ATM-10ID

BP/ATM-10ID

Eaton

FUSE AUTO 10A 32VAC/VDC 1=2 PCS

0

AGU-40GP

AGU-40GP

Eaton

BUSS MIDGET FUSE FAST ACTING

0

BK/GBH-V025A6F

BK/GBH-V025A6F

Eaton

FUSE CERAMIC 25A 500VAC AXIAL

0

ATL-7-1/2

ATL-7-1/2

Eaton

FUSE MICRO III BLADE 3 LEG 7.5 A

0

AT-25

AT-25

Eaton

BLADE FUSE

0

AGU-3

AGU-3

Eaton

BUSS MIDGET FUSE FAST ACTING

0

RSFB1008

RSFB1008

Eaton

FUSEBANK 100A 660V AC 8 WAY

0

BK/ATR-15

BK/ATR-15

Eaton

FUSE MICRO II BLADE

0

AGU-4

AGU-4

Eaton

BUSS MIDGET FUSE FAST ACTING

0

BP/ATC-35ID

BP/ATC-35ID

Eaton

FUSE AUTO 35A 32VAC 1=5 PCS

0

BK/FMM-25

BK/FMM-25

Eaton

FUSE AUTO 25A 32VDC AUTO LINK

0

ATR-25

ATR-25

Eaton

FUSE MICRO II BLADE 2 LEG 25 AMP

0

BP/FMX-50ID

BP/FMX-50ID

Eaton

FUSE FMX-50 AMP EASYID 1 PER CAR

0

RSFB1004

RSFB1004

Eaton

FUSEBANK 100A 660V AC 4 WAY

0

AGU-3-1J0281

AGU-3-1J0281

Eaton

BUSS MIDGET FUSE FAST ACTING

0

FMX-40

FMX-40

Eaton

FUSE AUTO 40A AUTO LINK

0

AMG-500

AMG-500

Eaton

AMG HI-AMP STUD MOUNT FUSE 500A

0

BK/MAX-70

BK/MAX-70

Eaton

FUSE AUTO 70A 32VDC BLADE

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top