Fuses

Image Part Number Description / PDF Quantity Rfq
QA2410F1A25T

QA2410F1A25T

AEM

AUTOMOTIVE FUSE, 1.25A, 250VDC

2000

QA2410F1A00T

QA2410F1A00T

AEM

AUTOMOTIVE FUSE, 1A, 250VDC

2000

QF0603GA500T

QF0603GA500T

AEM

AUTOMOTIVE FUSE, 0.5A, 65VDC

3000

QF1206F1A75T

QF1206F1A75T

AEM

AUTOMOTIVE FUSE, 1.75A, 63VDC

3000

QF1206FA500T

QF1206FA500T

AEM

AUTOMOTIVE FUSE, 0.5A, 63VDC

0

QF0603F2A50T

QF0603F2A50T

AEM

AUTOMOTIVE FUSE, 2.5A, 32VDC

3000

QF1206HA750T

QF1206HA750T

AEM

AUTOMOTIVE FUSE, 0.75A, 65VDC

3000

QA1206F8A00T

QA1206F8A00T

AEM

AUTOMOTIVE FUSE, 8A, 32VDC

3000

QF1206F6A00T

QF1206F6A00T

AEM

AUTOMOTIVE FUSE, 6A, 32VDC

3000

QF0603H1A50T

QF0603H1A50T

AEM

AUTOMOTIVE FUSE, 1.5A, 32VDC

4000

QF1206H2A00T

QF1206H2A00T

AEM

AUTOMOTIVE FUSE, 2A, 63VDC

3000

QA1206F2A00T

QA1206F2A00T

AEM

AUTOMOTIVE FUSE, 2A, 110VDC

3000

QF1206H1A00T

QF1206H1A00T

AEM

AUTOMOTIVE FUSE, 1A, 63VDC

3000

QF1206G1A50T

QF1206G1A50T

AEM

AUTOMOTIVE FUSE, 1.5A, 65VDC

3000

QF1206HA500T

QF1206HA500T

AEM

AUTOMOTIVE FUSE, 0.5A, 65VDC

3000

QA2410F15A0T

QA2410F15A0T

AEM

AUTOMOTIVE FUSE, 15A, 65VDC

2000

QF1206H6A00T

QF1206H6A00T

AEM

AUTOMOTIVE FUSE, 6A, 24VDC

3000

QA2410F10A0T

QA2410F10A0T

AEM

AUTOMOTIVE FUSE, 10A, 125VDC

2000

QF0603H1A00T

QF0603H1A00T

AEM

AUTOMOTIVE FUSE, 1A, 32VDC

4000

QF1206G2A00T

QF1206G2A00T

AEM

AUTOMOTIVE FUSE, 2A, 65VDC

3000

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top