Fuses

Image Part Number Description / PDF Quantity Rfq
BK/AGC-V-3-R

BK/AGC-V-3-R

PowerStor (Eaton)

FUSE GLASS 3A 250VAC 3AB 3AG

495

BK/S506-V-6.3-R

BK/S506-V-6.3-R

PowerStor (Eaton)

FUSE GLASS 6.3A 250VAC 5X20MM

0

BK1/GMA-10-R

BK1/GMA-10-R

PowerStor (Eaton)

FUSE GLASS 10A 125VAC 5X20MM

761

BK/MDQ-1/32

BK/MDQ-1/32

PowerStor (Eaton)

FUSE GLASS 31MA 250VAC 3AB 3AG

0

S506-200-R

S506-200-R

PowerStor (Eaton)

FUSE GLASS 200MA 250VAC 5X20MM

930

BK-S505H-V-1.6-R

BK-S505H-V-1.6-R

PowerStor (Eaton)

FUSE CERAMIC 1.6A 600VAC 400VDC

1000

BK/GMW-6/10

BK/GMW-6/10

PowerStor (Eaton)

FUSE BOARD MNT 600MA 125VAC RAD

0

BK/GMD-1-R

BK/GMD-1-R

PowerStor (Eaton)

FUSE GLASS 1A 250VAC 5X20MM

700

S505-5-R

S505-5-R

PowerStor (Eaton)

FUSE CERAMIC 5A 250VAC 5X20MM

0

BK/MDA-30-R

BK/MDA-30-R

PowerStor (Eaton)

FUSE CERM 30A 250VAC 125VDC 3AB

2874400

BK1-S505H-1-R

BK1-S505H-1-R

PowerStor (Eaton)

FUSE CERM 1A 600VAC 400VDC 5X20

1133

GMA-1.25-R

GMA-1.25-R

PowerStor (Eaton)

FUSE GLASS 1.25A 250VAC 5X20MM

0

BK/C518-250-R

BK/C518-250-R

PowerStor (Eaton)

FUSE GLASS 250MA 250VAC 2AG

82

SR-5-6.3A-AP

SR-5-6.3A-AP

PowerStor (Eaton)

FUSE BOARD MOUNT 6.3A 250VAC RAD

1449

AGC-6/10-R

AGC-6/10-R

PowerStor (Eaton)

FUSE GLASS 600MA 250VAC 3AB 3AG

0

BK/MDL-V-2-R

BK/MDL-V-2-R

PowerStor (Eaton)

FUSE GLASS 2A 250VAC 3AB 3AG

458

BK/GFA-12

BK/GFA-12

PowerStor (Eaton)

FUSE BOARD MOUNT 12A 32VAC AXIAL

0

BK/MDL-V-1/4

BK/MDL-V-1/4

PowerStor (Eaton)

FUSE GLASS 250MA 250VAC 3AB 3AG

0

BK-S505H-V-1.25-R

BK-S505H-V-1.25-R

PowerStor (Eaton)

FUSE CERAMIC 1.25A 600VAC 400VDC

0

BK/S500-160-R

BK/S500-160-R

PowerStor (Eaton)

FUSE GLASS 160MA 250VAC 5X20MM

229

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top