Fuses

Image Part Number Description / PDF Quantity Rfq
SF-1206SP050-2

SF-1206SP050-2

J.W. Miller / Bourns

FUSE BOARD MNT 500MA 63VDC 1206

318

SF-0402FP050-2

SF-0402FP050-2

J.W. Miller / Bourns

FUSE BOARD MNT 500MA 32VDC 0402

3340

SF-0402S300M-2

SF-0402S300M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 3A 24VDC 0402

7655

SF-0603SP050-2

SF-0603SP050-2

J.W. Miller / Bourns

FUSE BOARD MNT 500MA 50VDC 0603

3074

SF-1206FP300-2

SF-1206FP300-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 3A 32VDC 1206

3832

SF-0603HI450M-2

SF-0603HI450M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 4.5A 32VDC 0603

4000

SF-1206SA200W-2

SF-1206SA200W-2

J.W. Miller / Bourns

FUSE 1206

2470

SF-1206S600M-2

SF-1206S600M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 6A 32VDC 1206

18339

SF-2923HC40C-2

SF-2923HC40C-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 40A 60VDC 2SMD

776

SF-2410FP016T-2

SF-2410FP016T-2

J.W. Miller / Bourns

FUSE BRD 160MA 125VAC/125VDC SMD

2739

SF-0402FP200F-2

SF-0402FP200F-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 2A 35VDC 0402

0

SF-2410FP315W-2

SF-2410FP315W-2

J.W. Miller / Bourns

FUSE BRD 3.15A 125VAC/125DC 2410

870

SF-0603SP125-2

SF-0603SP125-2

J.W. Miller / Bourns

FUSE BOARD MNT 1.25A 32VDC 0603

0

SF-2410FPA800W-2

SF-2410FPA800W-2

J.W. Miller / Bourns

FUSE 2410

379

SF-0603SP450M-2

SF-0603SP450M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 4.5A 32VDC 0603

0

SF-2410SP100W-2

SF-2410SP100W-2

J.W. Miller / Bourns

FUSE BRD MT 1A 250VAC/125DC 2410

1113

SF-0402S075-2

SF-0402S075-2

J.W. Miller / Bourns

FUSE BOARD MNT 750MA 24VDC 0402

0

SF-0603SP700M-2

SF-0603SP700M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 7A 32VDC 0603

2969

SF-1206S300M-2

SF-1206S300M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 3A 32VDC 1206

2639

SF-1206FP700-2

SF-1206FP700-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 7A 32VDC 1206

4589

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top