Fuses

Image Part Number Description / PDF Quantity Rfq
0680L3000-15

0680L3000-15

Bel Fuse, Inc.

FUSE BRICK SMD 2410 SLOW 3A

0

0685P3500-01

0685P3500-01

Bel Fuse, Inc.

FUSE 3.5A 63VDC FAST 1206 SMD

260

MRT 6.3AMMO

MRT 6.3AMMO

Bel Fuse, Inc.

FUSE BOARD MOUNT 6.3A 250VAC RAD

3336

0ADKP4000-RE

0ADKP4000-RE

Bel Fuse, Inc.

FUSE CERAMIC 4A 600VAC/500VDC

105

C1Q 3

C1Q 3

Bel Fuse, Inc.

FUSE BOARD MOUNT 3A 125VAC 63VDC

71252

3AG 6-R

3AG 6-R

Bel Fuse, Inc.

FUSE GLASS 6A 250VAC 3AB 3AG

0

0680L0500-21

0680L0500-21

Bel Fuse, Inc.

FUSE BRICK SMD 2410 SLOW 500MA

0

3SB 5-R

3SB 5-R

Bel Fuse, Inc.

FUSE GLASS 5A 250VAC 3AB 3AG

0

0659C4000-12

0659C4000-12

Bel Fuse, Inc.

FUSE CERAMIC 4A 250VAC 5X20MM

220

MRT 4-BULK

MRT 4-BULK

Bel Fuse, Inc.

FUSE BOARD MOUNT 4A 250VAC RAD

1898

0679H0500-05

0679H0500-05

Bel Fuse, Inc.

FUSE BRD MNT 500MA 350VAC 72VDC

6501

3SB 12-R

3SB 12-R

Bel Fuse, Inc.

FUSE GLASS 12A 125VAC 3AB 3AG

1197

2JQ 3-R

2JQ 3-R

Bel Fuse, Inc.

FUSE GLASS 3A 350VAC 140VDC 2AG

640

0ADKP0800-RE

0ADKP0800-RE

Bel Fuse, Inc.

FUSE CERAMIC 0.8A 600VAC/500VDC

881

0679H9150-05

0679H9150-05

Bel Fuse, Inc.

FUSE BOARD MNT 15A 350VAC 60VDC

692

0680L0500-25

0680L0500-25

Bel Fuse, Inc.

FUSE BRICK SMD 2410 SLOW 500MA

0

0679H1500-05

0679H1500-05

Bel Fuse, Inc.

FUSE BOARD MNT 1.5A 350VAC 72VDC

5032

5HTP 1-R

5HTP 1-R

Bel Fuse, Inc.

FUSE CERAMIC 1A 250VAC 5X20MM

973

UMTS 1.6

UMTS 1.6

Bel Fuse, Inc.

FUSE BOARD MNT 1.6A 250VAC 2SMD

0

3JS 1.5-R TR

3JS 1.5-R TR

Bel Fuse, Inc.

FUSE GLASS 1.5A 350VAC 140VDC

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top