Fuses

Image Part Number Description / PDF Quantity Rfq
0698Q2000-01

0698Q2000-01

Bel Fuse, Inc.

FUSE 2A 350V RADIAL

867

0ADAC2500-BE

0ADAC2500-BE

Bel Fuse, Inc.

FUSE CERM 2.5A 600VAC/VDC

152

5ST 8-R

5ST 8-R

Bel Fuse, Inc.

FUSE GLASS 8A 250VAC 5X20MM

4423

0679L0750-01

0679L0750-01

Bel Fuse, Inc.

FUSE BRD MNT 750MA 125VAC/VDC

0

0697W2000-02

0697W2000-02

Bel Fuse, Inc.

FUSE 2A 350V RADIAL

2826

0697H5000-01

0697H5000-01

Bel Fuse, Inc.

FUSE BRD MNT 5A 350VAC 72VDC

383

3AB 4-R

3AB 4-R

Bel Fuse, Inc.

FUSE CERAMIC 4A 250VAC 3AB 3AG

734

MRT 2-BULK

MRT 2-BULK

Bel Fuse, Inc.

FUSE BOARD MOUNT 2A 250VAC RAD

0

5HT 3.15-R

5HT 3.15-R

Bel Fuse, Inc.

FUSE CERAMIC 3.15A 250VAC 5X20MM

319

0686F3500-01

0686F3500-01

Bel Fuse, Inc.

FUSE BRD MNT 3.5A 63VDC 0603

5504

5TT 5-R

5TT 5-R

Bel Fuse, Inc.

FUSE GLASS 5A 125VAC 5X20MM

766

0ADHC0440-BE

0ADHC0440-BE

Bel Fuse, Inc.

FUSE CERM 0.44A 1000VAC/VDC

174

0685P5000-01

0685P5000-01

Bel Fuse, Inc.

FUSE 5A 63VDC FAST 1206 SMD

4705

0ADEP9150-RE

0ADEP9150-RE

Bel Fuse, Inc.

FUSE CERAMIC 15A 500VAC/VDC 3AB

465

5STP 100-R

5STP 100-R

Bel Fuse, Inc.

FUSE GLASS 100MA 250VAC 5X20MM

409

0ADKP9160-RE

0ADKP9160-RE

Bel Fuse, Inc.

FUSE CERAMIC 16A 600VAC/500VDC

0

0659P2000-13

0659P2000-13

Bel Fuse, Inc.

FUSE CERAMIC 2A 250VAC 5X20MM

0

0ADAC2000-BE

0ADAC2000-BE

Bel Fuse, Inc.

FUSE CERM 2A 600VAC/VDC

257

C1Q 250

C1Q 250

Bel Fuse, Inc.

FUSE BRD MNT 250MA 125VAC 63VDC

4750

2JQ 500-R

2JQ 500-R

Bel Fuse, Inc.

FUSE GLASS 500MA 350VAC 140VDC

183

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top