Fuses

Image Part Number Description / PDF Quantity Rfq
0680L3500-05

0680L3500-05

Bel Fuse, Inc.

FUSE BRICK SMD 2410 SLOW 3.5A

4105

0ADAC0600-BE

0ADAC0600-BE

Bel Fuse, Inc.

FUSE CERM 0.6A 600VAC/VDC

9687

GSAP 10-R

GSAP 10-R

Bel Fuse, Inc.

FUSE CERAMIC 10A 125VAC 3AB 3AG

0

0659C1250-12

0659C1250-12

Bel Fuse, Inc.

FUSE CERAMIC 1.25A 250VAC 5X20MM

309

MRT 1-BULK-SHORT

MRT 1-BULK-SHORT

Bel Fuse, Inc.

FUSE 1A 250/277V RADIAL

0

RSTA 1.25 BULK, SHORT LEAD

RSTA 1.25 BULK, SHORT LEAD

Bel Fuse, Inc.

FUSE BRD MNT 1.25A 250VAC/63VDC

0

0697H9120-05

0697H9120-05

Bel Fuse, Inc.

FUSE BRD MNT 12A 350VAC 72VDC

310

RST 6.3-BULK

RST 6.3-BULK

Bel Fuse, Inc.

FUSE BOARD MOUNT 6.3A 250VAC RAD

0

RSTA 1 BULK, SHORT LEAD

RSTA 1 BULK, SHORT LEAD

Bel Fuse, Inc.

FUSE BRD MNT 1A 250VAC/63VDC RAD

0

0679H0250-05

0679H0250-05

Bel Fuse, Inc.

FUSE BRD MNT 250MA 350VAC 72VDC

0

C1F 1

C1F 1

Bel Fuse, Inc.

FUSE 1.0A 125VAC FAST 1206

0

MRF 500-BULK

MRF 500-BULK

Bel Fuse, Inc.

FUSE BRD MNT 500MA 250VAC RADIAL

892

GSA 1.6-R

GSA 1.6-R

Bel Fuse, Inc.

FUSE CERAMIC 1.6A 250VAC 3AB 3AG

0

0679L9200-01

0679L9200-01

Bel Fuse, Inc.

FUSE BRD MNT 20A 125VAC/VDC

3518

SSQ 1.5/5K

SSQ 1.5/5K

Bel Fuse, Inc.

FUSE BRD MNT 1.5A 125VAC/VDC SMD

9990

0697H0315-02

0697H0315-02

Bel Fuse, Inc.

FUSE BRD MNT 315MA 350VAC 100VDC

0

5TT 3.15-R

5TT 3.15-R

Bel Fuse, Inc.

FUSE GLASS 3.15A 125VAC 5X20MM

195

RST 400 AMMO

RST 400 AMMO

Bel Fuse, Inc.

FUSE BRD MNT 400MA 250VAC RADIAL

0

5ETP 1-R

5ETP 1-R

Bel Fuse, Inc.

FUSE GLASS 1A 250VAC 5X20MM

739

0679H4000-05

0679H4000-05

Bel Fuse, Inc.

FUSE BOARD MNT 4A 350VAC 60VDC

1825

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email