Fuses

Image Part Number Description / PDF Quantity Rfq
3-103-093

3-103-093

Schurter

MGA-A FUSE 375MA SOLID STATE THI

50

3404.2323.11

3404.2323.11

Schurter

FUSE BOARD MNT 750MA 125VAC/VDC

100

3403.0284.23

3403.0284.23

Schurter

FUSE BRD MNT 10A 250VAC/125VDC

0

3403.0280.11

3403.0280.11

Schurter

FUSE BRD MNT 4A 277VAC/125VDC

4441

3402.0045.22

3402.0045.22

Schurter

FUSE BRD MNT 500MA 63VAC/VDC SMD

0

0034.7105

0034.7105

Schurter

FUSE BRD MNT 100MA 250VAC RADIAL

353

0001.2512.PT

0001.2512.PT

Schurter

FUSE CERAMIC 6.3A 250VAC 150VDC

1985

0034.5713.22

0034.5713.22

Schurter

FUSE GLASS 1A 250VAC 5X20MM

0

3404.2464.11

3404.2464.11

Schurter

FUSE BRD MNT 250VAC/125VDC 2SMD

93

3403.0289.11

3403.0289.11

Schurter

FUSE BRD MNT 30A 250VAC/72VDC

1308

7100.1064.13

7100.1064.13

Schurter

FUSE BOARD MNT 800MA 250VAC/VDC

92

0034.3774

0034.3774

Schurter

FUSE GLASS 800MA 250VAC 5X20MM

16

0001.1007

0001.1007

Schurter

FUSE CERAMIC 2A 250VAC 5X20MM

19509000

3403.0173.24

3403.0173.24

Schurter

FUSE BOARD MNT 5A 250VAC 125VDC

6140

0034.6722

0034.6722

Schurter

FUSE BRD MNT 5A 250VAC 63VDC RAD

36

0034.3422

0034.3422

Schurter

FUSE GLASS 3.15A 250VAC 3AB 3AG

150

0034.1523.PT

0034.1523.PT

Schurter

FUSE GLASS 5A 250VAC 5X20MM

630

3404.0121.24

3404.0121.24

Schurter

FUSE BRD MNT 5A 125VAC/VDC 2SMD

0

0001.1035

0001.1035

Schurter

FUSE GLASS 12.5A 250VAC 3AB 3AG

20

0034.7122

0034.7122

Schurter

FUSE BOARD MOUNT 5A 250VAC RAD

35

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top