Fuses

Image Part Number Description / PDF Quantity Rfq
0034.3130

0034.3130

Schurter

FUSE GLASS 20A 250VAC 5X20MM

35791000

0034.5036

0034.5036

Schurter

FUSE GLASS 200MA 250VAC 5X20MM

1195

3402.0048.24

3402.0048.24

Schurter

FUSE BRD MNT 3.15A 63VAC/VDC SMD

0

7010.9965.63

7010.9965.63

Schurter

FUSE BOARD MNT 3.15A 125VAC/VDC

932

0034.7211

0034.7211

Schurter

FUSE BOARD MNT 400MA 250VAC RAD

97

3403.0155.24

3403.0155.24

Schurter

FUSE BRD MNT 80MA 250VAC 125VDC

2930

3402.0017.24

3402.0017.24

Schurter

FUSE BOARD MNT 5A 63VAC/VDC 2SMD

0

7010.6340.13

7010.6340.13

Schurter

FUSE BOARD MNT 500MA 125VAC/VDC

195

0034.2517

0034.2517

Schurter

FUSE GLASS 1.25A 250VAC 125VDC

2

0001.1008

0001.1008

Schurter

FUSE CERAMIC 2.5A 250VAC 5X20MM

1028

0034.6048

0034.6048

Schurter

FUSE BOARD MOUNT 2.5A 250VAC RAD

192

0034.7321

0034.7321

Schurter

FUSE BOARD MOUNT 4A 250VAC RAD

549

0034.5718.11

0034.5718.11

Schurter

FUSE GLASS 3.15A 250VAC 5X20MM

0

8020.5074.PT

8020.5074.PT

Schurter

FUSE CERAMIC 4A 500VAC 3AB 3AG

438

0034.6018

0034.6018

Schurter

FUSE BOARD MOUNT 2.5A 250VAC RAD

446

0001.1030

0001.1030

Schurter

FUSE GLASS 4A 250VAC 3AB 3AG

190

3405.0165.24

3405.0165.24

Schurter

UMF 250 FUSE 800MA F SMT

1996

3413.0326.22

3413.0326.22

Schurter

FUSE BRD MNT 7A 32VAC 63VDC 1206

47956

3404.2422.22

3404.2422.22

Schurter

FUSE BOARD MNT 4A 277VAC 250VDC

461000

0034.5138

0034.5138

Schurter

FUSE GLASS 4A 250VAC 3AB 3AG

66

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top