Fuses

Image Part Number Description / PDF Quantity Rfq
3412.0124.24

3412.0124.24

Schurter

FUSE BRD MNT 5A 36VAC 63VDC 0603

0

8020.5071.PT

8020.5071.PT

Schurter

FUSE CERAMIC 2A 500VAC 3AB 3AG

312

7030.3250

7030.3250

Schurter

FUSE GLASS 250MA 220VAC 125VDC

44

3410.0037.03

3410.0037.03

Schurter

FUSE BRD MNT 3A 125VAC/VDC 2SMD

0

3403.0015.11

3403.0015.11

Schurter

FUSE BOARD MNT 800MA 250VAC/VDC

119

3403.0176.24

3403.0176.24

Schurter

FUSE BOARD MNT 10A 250VAC 125VDC

0

3410.0031.03

3410.0031.03

Schurter

FUSE BRD MNT 1A 125VAC/VDC 2SMD

0

3-103-107

3-103-107

Schurter

MGA-A FUSE 1A SOLID STATE THIN F

2945

8020.5024

8020.5024

Schurter

FUSE CERAMIC 20A 400VAC/63VDC

1649

0034.6944

0034.6944

Schurter

FUSE BOARD MNT 800MA 250VAC RAD

94

3402.0040.11

3402.0040.11

Schurter

FUSE BRD MNT 10A 63VAC/VDC 2SMD

27977200

0034.3426

0034.3426

Schurter

FUSE GLASS 8A 250VAC 3AB 3AG

0

3414.0117.26

3414.0117.26

Schurter

FUSE BOARD MOUNT 1.5A 32VDC 0402

1565

3413.0115.22

3413.0115.22

Schurter

FUSE BRD MNT 1A 32VAC 63VDC 1206

258

0034.5214

0034.5214

Schurter

FUSE GLASS 250MA 250VAC 3AB 3AG

70

0034.7308

0034.7308

Schurter

FUSE BOARD MNT 200MA 250VAC RAD

730

0001.2501.PT

0001.2501.PT

Schurter

FUSE CERAMIC 500MA 250VAC 300VDC

0

0001.2524

0001.2524

Schurter

FUSE GLASS 1A 250VAC 63VDC 3AB

173

3403.0122.24

3403.0122.24

Schurter

FUSE BOARD MOUNT 4A 125VAC 2SMD

0

0001.2508

0001.2508

Schurter

FUSE CERAMIC 2.5A 250VAC 300VDC

56272000

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top