Fuses

Image Part Number Description / PDF Quantity Rfq
3413.0216.22

3413.0216.22

Schurter

FUSE BRD MNT 1A 32VAC 63VDC 1206

0

0001.2513.TR

0001.2513.TR

Schurter

FUSE CERM 8A 250VAC 150VDC 5X20

0

0001.1011

0001.1011

Schurter

FUSE CERAMIC 5A 250VAC 5X20MM

33664000

0034.3111

0034.3111

Schurter

FUSE GLASS 250MA 250VAC 5X20MM

60913000

3413.0213.26

3413.0213.26

Schurter

FUSE BOARD MNT 500MA 32VAC 63VDC

0

3413.0213.24

3413.0213.24

Schurter

FUSE BOARD MNT 500MA 32VAC 63VDC

0

3403.0168.24

3403.0168.24

Schurter

FUSE BRD MNT 1.6A 250VAC 125VDC

7006

0034.5718.22

0034.5718.22

Schurter

FUSE GLASS 3.15A 250VAC 5X20MM

0

3403.0011.11

3403.0011.11

Schurter

FUSE BOARD MNT 315MA 250VAC/VDC

55

0034.6611

0034.6611

Schurter

FUSE BRD MNT 400MA 250VAC 125VDC

719

7100.1169.95

7100.1169.95

Schurter

FUSE BRD MNT 2.5A 250VAC/VDC RAD

0

3403.0280.23

3403.0280.23

Schurter

FUSE BRD MNT 4A 277VAC/125VDC

1895312000

3403.0282.23

3403.0282.23

Schurter

FUSE BRD MNT 6.3A 277VAC/125VDC

2445

0034.6949

0034.6949

Schurter

FUSE BOARD MOUNT 2.5A 250VAC RAD

60

0034.3125.TR

0034.3125.TR

Schurter

FUSE GLASS 6.3A 250VAC 5X20MM

0

0034.5614.22

0034.5614.22

Schurter

FUSE GLASS 500MA 250VAC 5X20MM

0

0034.5215

0034.5215

Schurter

FUSE GLASS 300MA 250VAC 3AB 3AG

285

0034.1519

0034.1519

Schurter

FUSE GLASS 2A 250VAC 5X20MM

17553

0034.3417

0034.3417

Schurter

FUSE GLASS 1A 250VAC 3AB 3AG

11

3-103-105

3-103-105

Schurter

MGA-A FUSE 1A SOLID STATE THIN F

90

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top