Fuses

Image Part Number Description / PDF Quantity Rfq
3403.0132.24

3403.0132.24

Schurter

FUSE BOARD MNT 3.5A 125VAC 2SMD

0

0001.2531

0001.2531

Schurter

FUSE GLASS 5A 250VAC 63VDC 3AB

1466

3403.0160.11

3403.0160.11

Schurter

FUSE BRD MNT 250MA 250VAC 125VDC

11855

7100.1163.96

7100.1163.96

Schurter

FUSE BOARD MNT 630MA 250VAC/VDC

0

0034.6010

0034.6010

Schurter

FUSE BOARD MNT 400MA 250VAC RAD

0

3403.0272.11

3403.0272.11

Schurter

FUSE 630MA 277AC/250DC T-LAG SMD

91

0034.3125.PT

0034.3125.PT

Schurter

FUSE GLASS 6.3A 250VAC 5X20MM

0

0001.1036

0001.1036

Schurter

FUSE GLASS 16A 250VAC 3AB 3AG

525

7022.0550

7022.0550

Schurter

FUSE CERM 315MA 500VAC 3AB 3AG

29

3410.0037.02

3410.0037.02

Schurter

FUSE BRD MNT 3A 125VAC/VDC 2SMD

1462

0034.6720

0034.6720

Schurter

FUSE BRD MNT 3.15A 250VAC 125VDC

91

0034.7119

0034.7119

Schurter

FUSE BOARD MOUNT 2.5A 250VAC RAD

85

7100.1166.13

7100.1166.13

Schurter

FUSE BOARD MNT 1.25A 250VAC/VDC

94

7043.8220

7043.8220

Schurter

FUSE CERAMIC 16A 250VAC 3AB 3AG

0

0034.6602

0034.6602

Schurter

FUSE BRD MNT 50MA 250VAC 125VDC

3753300

3403.0170.24

3403.0170.24

Schurter

FUSE BRD MNT 2.5A 250VAC 125VDC

1495

0001.2706.11

0001.2706.11

Schurter

FUSE CERAMIC 1.6A 250VAC 300VDC

4209

3405.0176.24

3405.0176.24

Schurter

FUSE BOARD MNT 10A 250VAC 125VDC

3144

0034.5217

0034.5217

Schurter

FUSE GLASS 375MA 250VAC 3AB 3AG

193

3410.0022.03

3410.0022.03

Schurter

FUSE BOARD MNT 250MA 125VAC/VDC

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top