Fuses

Image Part Number Description / PDF Quantity Rfq
0001.2516.PT

0001.2516.PT

Schurter

FUSE CERM 16A 250VAC 125VDC 5X20

5755

3405.0174.24

3405.0174.24

Schurter

UMF 250 FUSE 6.3A F SMT

619

7022.0640

7022.0640

Schurter

FUSE CERAMIC 2.5A 500VAC 3AB 3AG

225

3402.0012.24

3402.0012.24

Schurter

FUSE BOARD MNT 2A 63VAC/VDC SMD

16645

3402.0048.11

3402.0048.11

Schurter

FUSE BRD MNT 3.15A 63VAC/VDC SMD

445

3413.0218.26

3413.0218.26

Schurter

FUSE BOARD MNT 1.6A 32VAC 63VDC

0

3414.0113.26

3414.0113.26

Schurter

FUSE BOARD MNT 500MA 32VDC 0402

8536

7100.1120.13

7100.1120.13

Schurter

FUSE BRD MNT 3.15A 250VAC RADIAL

100

8020.5068

8020.5068

Schurter

FUSE CERAMIC 1A 500VAC 3AB 3AG

1250

7043.8230

7043.8230

Schurter

FUSE CERAMIC 20A 250VAC 3AB 3AG

0

3412.0120.26

3412.0120.26

Schurter

FUSE BRD MNT 36VAC 32VDC 0603

0

0034.7304

0034.7304

Schurter

FUSE BOARD MOUNT 80MA 250VAC RAD

720

3402.0017.22

3402.0017.22

Schurter

FUSE BOARD MNT 5A 63VAC/VDC 2SMD

56281500

0034.4212

0034.4212

Schurter

FUSE BOARD MNT 200MA 125VAC/VDC

64

3405.0173.11

3405.0173.11

Schurter

UMF 250 FUSE 5A F SMT

354

8020.5020

8020.5020

Schurter

FUSE CARTRIDGE CERAMIC 8A 500V

0

3413.0222.24

3413.0222.24

Schurter

FUSE BRD MNT 4A 32VAC 63VDC 1206

0

0001.1022

0001.1022

Schurter

FUSE GLASS 630MA 250VAC 3AB 3AG

70

3-103-125

3-103-125

Schurter

MGA-A FUSE 4A SOLID STATE THIN F

94

0001.2516.TR

0001.2516.TR

Schurter

FUSE CERM 16A 250VAC 125VDC 5X20

936

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top