Fuses

Image Part Number Description / PDF Quantity Rfq
ANX58-UL-50A

ANX58-UL-50A

OptiFuse

FUSE AUTO 50A 58VDC BLADE MAX

0

5STP 1-R

5STP 1-R

Bel Fuse, Inc.

FUSE GLASS 1A 250VAC 5X20MM

642

0034.5109

0034.5109

Schurter

FUSE GLASS 150MA 250VAC 3AB 3AG

40

0034.6009

0034.6009

Schurter

FUSE BOARD MNT 315MA 250VAC RAD

1623

0160001.MR

0160001.MR

Wickmann / Littelfuse

FUSE BOARD MOUNT 1A 250VAC 2SMD

0

5HF 10-R

5HF 10-R

Bel Fuse, Inc.

FUSE CERAMIC 10A 250VAC 5X20MM

0

0001.2516

0001.2516

Schurter

FUSE CERM 16A 250VAC 125VDC 5X20

11681000

SS-5-2A-BK

SS-5-2A-BK

PowerStor (Eaton)

FUSE BOARD MOUNT 2A 250VAC RAD

0

3402.0047.24

3402.0047.24

Schurter

FUSE BRD MNT 1.5A 63VAC/VDC 2SMD

0

FC-5432-15A-C5-C

FC-5432-15A-C5-C

Delta Electronics

SMD FUSE RATED CURRENT 15A/35VDC

1995

3404.2411.22

3404.2411.22

Schurter

FUSE BRD MNT 315MA 277VAC 250VDC

0

TR/3216FF2-R

TR/3216FF2-R

PowerStor (Eaton)

FUSE BRD MNT 2A 32VAC 63VDC 1206

73157

0313002.VXP

0313002.VXP

Wickmann / Littelfuse

FUSE GLASS 2A 250VAC 3AB 3AG

0

BK/S506-V-2-R

BK/S506-V-2-R

PowerStor (Eaton)

FUSE GLASS 2A 250VAC 5X20MM

0

MID-200A

MID-200A

OptiFuse

LIMITER FUSE, FAST-ACTING, 200A

838

MDL-V-9-R

MDL-V-9-R

PowerStor (Eaton)

FUSE GLASS 9A 32VAC 3AB 3AG

0

BK1/S501-1.6-R

BK1/S501-1.6-R

PowerStor (Eaton)

FUSE CERAMIC 1.6A 250VAC 5X20MM

930

3AB 1.6-R

3AB 1.6-R

Bel Fuse, Inc.

FUSE CERAMIC 1.6A 250VAC 3AB 3AG

0

0224006.VXUP

0224006.VXUP

Wickmann / Littelfuse

FUSE GLASS 6A 125VAC 2AG

0

39211000440

39211000440

Wickmann / Littelfuse

FUSE BOARD MNT 1A 250VAC RADIAL

1159

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top