Fuses

Image Part Number Description / PDF Quantity Rfq
5STP 100-R

5STP 100-R

Bel Fuse, Inc.

FUSE GLASS 100MA 250VAC 5X20MM

409

0407004.WR

0407004.WR

Wickmann / Littelfuse

FUSE 1206 63V T-LAG 4A

2963

SF-2410FP025T-2

SF-2410FP025T-2

J.W. Miller / Bourns

FUSE BRD 250MA 125VAC/125VDC SMD

1534

0001.2506

0001.2506

Schurter

FUSE CERAMIC 1.6A 250VAC 300VDC

9952000

BK/AGC-V-3/4-R

BK/AGC-V-3/4-R

PowerStor (Eaton)

FUSE GLASS 750MA 250VAC 3AB 3AG

0

37302500410

37302500410

Wickmann / Littelfuse

FUSE BOARD MNT 250MA 250VAC RAD

0

BK/GMW-1/8

BK/GMW-1/8

PowerStor (Eaton)

FUSE BRD MNT 125MA 125VAC RADIAL

0

0ADKP9160-RE

0ADKP9160-RE

Bel Fuse, Inc.

FUSE CERAMIC 16A 600VAC/500VDC

0

0603SFP400F/32-2

0603SFP400F/32-2

Wickmann / Littelfuse

FUSE BOARD MOUNT 4A 32VDC 0603

0

ANM-I-20A

ANM-I-20A

OptiFuse

FUSE AUTO 20A 32VDC BLADE MINI

0

8020.0605

8020.0605

Schurter

FUSE CERAMIC 20A 250VAC 3AB 3AG

778620

7010.9917.03

7010.9917.03

Schurter

FUSE BRD MNT 15A 65VAC/VDC 2SMD

84

74-4SG375MA

74-4SG375MA

NTE Electronics, Inc.

FUSE GLASS 375MA 250VAC 2AG

1656

3-103-122

3-103-122

Schurter

MGA-A FUSE 3A SOLID STATE THIN F

742750

TCC-2A

TCC-2A

OptiFuse

CERAMIC - 5X20MM (UL), SLOW 2A

780

39612000000

39612000000

Wickmann / Littelfuse

FUSE BOARD MOUNT 2A 125VAC RAD

65

AGC-1/8-R

AGC-1/8-R

PowerStor (Eaton)

FUSE GLASS 125MA 250VAC 3AB 3AG

0

0001.2511.TR

0001.2511.TR

Schurter

FUSE CERM 5A 250VAC 150VDC 5X20

930

0215008.MXF103SPP

0215008.MXF103SPP

Wickmann / Littelfuse

FUSE CERAMIC 8A 250VAC RADIAL

0

0034.5243

0034.5243

Schurter

FUSE GLASS 7A 250VAC 3AB 3AG

272

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top