Fuseholders

Image Part Number Description / PDF Quantity Rfq
03450611ZX010

03450611ZX010

Wickmann / Littelfuse

FUSE HLDR CART 600V 20A PNL MNT

0

178.6152.0001

178.6152.0001

Wickmann / Littelfuse

FUSE HOLDER BLADE 80V CHASS MNT

0

0LEXBYCSX

0LEXBYCSX

Wickmann / Littelfuse

FUSE HLDR CART 600V 30A IN LINE

0

85200001009

85200001009

Wickmann / Littelfuse

FUSE HOLDER CART 250V 6.3A PCB

0

03420004HXL

03420004HXL

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

133

LFC600603C

LFC600603C

Wickmann / Littelfuse

FUSE BLOK CART 600V 60A DIN RAIL

431

L60030M2SQ

L60030M2SQ

Wickmann / Littelfuse

FUSE BLOCK CART 600V 30A CHASSIS

7617386

03540503Z

03540503Z

Wickmann / Littelfuse

FUSE BLOCK BLADE 120A PANEL MNT

121220

LFG600202CDINR

LFG600202CDINR

Wickmann / Littelfuse

FUSE BLOK CART 600V 20A DIN RAIL

240

PDM61001ZXM

PDM61001ZXM

Wickmann / Littelfuse

HWA20 ATO SEALED FUSEHOLDER

1

03590004Z

03590004Z

Wickmann / Littelfuse

FUSE BLOCK CART 250V 30A CHASSIS

20

01550300Z

01550300Z

Wickmann / Littelfuse

FUSE HLDR BLADE 32V 20A PNL MNT

616

FHAC0001XP

FHAC0001XP

Wickmann / Littelfuse

FUSE HLDR BLADE 32V 20A IN LINE

144

LPSC0003ZXID

LPSC0003ZXID

Wickmann / Littelfuse

FUSE HLDR CART 600V 30A DIN RAIL

131126

03420012HXL

03420012HXL

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

476

01050003H

01050003H

Wickmann / Littelfuse

FUSE CLIP CARTRIDGE 600V 15A PCB

29

0LEY00BAX

0LEY00BAX

Wickmann / Littelfuse

FUSE HLDR CART 600V 30A IN LINE

0

01270001Z

01270001Z

Wickmann / Littelfuse

FUSE CLIP CART 30A CHASS MNT

0

0LEX00CCX

0LEX00CCX

Wickmann / Littelfuse

FUSE HLDR CART 600V 30A IN LINE

0

0LEY00BDX

0LEY00BDX

Wickmann / Littelfuse

FUSE HLDR CART 600V 30A IN LINE

0

Fuseholders

1. Overview

Fuseholders are mechanical devices designed to safely house and connect fuses into electrical circuits. They ensure reliable mounting, electrical continuity, and safe isolation of fuses during overcurrent protection. As critical components in circuit protection systems, fuseholders prevent equipment damage and fire hazards by enabling controlled interruption of excessive current flow. Their importance spans industries such as power distribution, automotive, and industrial automation, where electrical safety and system reliability are paramount.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Panel Mount FuseholdersEnclosed design with front-accessible fuse compartmentIndustrial control panels, HVAC systems
Base Mount FuseholdersModular design with removable fuse basePower distribution units, electrical substations
Cartridge FuseholdersCylindrical design for DIN-rail mountingProcess automation systems, machinery
SMT (Surface Mount) FuseholdersMiniaturized PCB-mount designConsumer electronics, telecommunications

3. Structure and Components

Typical fuseholders consist of: - Insulating housing (thermoplastic/phenolic resin) - Contact springs (phosphor bronze or beryllium copper) - Fuse retention mechanism (screw/clamp terminals) - Terminal connections (solder tags, PCB pins, or cable lugs) - Arc suppression chamber (ceramic/insulating barriers) The design ensures mechanical stability, low contact resistance (<10m ), and dielectric strength up to 2500VAC.

4. Key Technical Specifications

ParameterTypical RangeImportance
Voltage Rating6-1000V AC/DCDetermines circuit compatibility
Current Rating0.5-630ADefines maximum operational current
Breaking Capacity10kA-50kASafety during fault conditions
Response Time1ms-10sProtection speed for sensitive components
Temperature Range-40 C to +125 CEnvironmental reliability
IP RatingIP20-IP67Protection against dust/water ingress

5. Application Fields

  • Energy: Solar inverters, battery management systems
  • Automotive: EV charging stations, ECU protection
  • Industrial: PLC control circuits, motor drives
  • Telecom: 5G base stations, network switches
  • Aerospace: Avionics power distribution

6. Leading Manufacturers and Products

ManufacturerKey Product SeriesNotable Features
LittelfusePOLO Panel MountModular design with visual indicators
MersenActi 9 seriesHigh breaking capacity (100kA)
EatonCircuit Protection EnclosuresUL94 V-0 rated materials
Bel Fuse0ZC SeriesSurface-mount with over-temperature cutoff

7. Selection Recommendations

Key considerations include: - Matching voltage/current ratings with system requirements - Environmental factors (temperature, vibration, humidity) - Accessibility requirements for fuse replacement - Compliance with standards (UL/IEC/EN) - Short-circuit current capacity of the installation - Mounting orientation and space constraints

Industry Trends and Future Outlook

Emerging trends include: - Miniaturization for EV and portable electronics - Integration with smart monitoring systems (IoT-enabled fuseholders) - Development of RoHS-compliant materials - High-voltage DC compatibility for renewable energy systems - Improved arc flash mitigation technologies The global market is projected to grow at 5.8% CAGR through 2027, driven by electric vehicle adoption and industrial automation demands.